Research on Heat Transfer Characteristics of Plate Evaporators for Cold Storage

被引:0
作者
Xu, Xun [1 ]
Yuan, Zhaokuo [2 ]
机构
[1] Nantong Univ, Xinglin Coll, Nantong 226000, Peoples R China
[2] Nanhua Heat Exchanger Mfg Co Ltd, Shanghai 201400, Peoples R China
关键词
plate evaporator; refrigeration capacity; pressure drop; numerical simulation; cold storage; FLOW;
D O I
10.3390/en17235837
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new type of plate evaporator suitable for cold storage refrigeration systems was designed. A mathematical model of the plate evaporator was established using Fluent14.0 software, and the effects of refrigerant mass flow rate and air velocity on the heat transfer characteristics of the plate evaporator were discussed. The numerical simulation results were verified through experiments. The research results show that in the design conditions of a refrigerant inlet dryness of 0.27, temperature of -5 degrees C, saturation pressure at this temperature, mass flow rate of 0.0187 kg/s, air inlet temperature of 6 degrees C, relative humidity of 80%, and flow rate of 3 m/s, the new plate evaporator had a cooling capacity of 3.13 kW, a refrigerant side pressure drop of 1.36 kPa, and an air side pressure drop of 495 Pa. By increasing the mass flow rate of the refrigerant or the air side flow rate, the cooling capacity of the evaporator increases linearly, but at the same time, the pressure drop on both the refrigerant and air sides increases rapidly.
引用
收藏
页数:18
相关论文
共 26 条
  • [1] Analysis of the flow and temperature distribution inside the compartment of a small refrigerator
    Belman-Flores, J. M.
    Gallegos-Munoz, A.
    [J]. APPLIED THERMAL ENGINEERING, 2016, 106 : 743 - 752
  • [2] [邓慧 Deng Hui], 2017, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V37, P826
  • [3] Ding Q., 2018, Simulation of Steam Condensation and Flow in Horizontal Tube
  • [4] [董超 Dong Chao], 2022, [制冷学报, Journal of Refrigeration], V43, P100
  • [5] Fan J., 2008, Advanced Applications and Example Analysis of Fluent
  • [6] Gu Y.F., 2023, Chin. J. Environ. Manag., V15, P61, DOI [10.16868/j.cnki.1674-6252.2023.04.061, DOI 10.16868/J.CNKI.1674-6252.2023.04.061]
  • [7] Experimental study on the Influence of Hydrogen Fraction on Self-acceleration of H2/CO/air laminar premixed flame
    Jiang, Yan-huan
    Li, Guo-xiu
    Li, Hong-meng
    Zhang, Guo-peng
    Lv, Jia-cheng
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (03) : 2351 - 2359
  • [8] Comparative evaluation of flow boiling heat transfer characteristics of R-1234ze(E) and R-134a in plate heat exchangers with different Chevron angles
    Kim, Dongwoo
    Lee, DongChan
    Jang, Dong Soo
    Jeon, Yongseok
    Kim, Yongchan
    [J]. APPLIED THERMAL ENGINEERING, 2018, 132 : 719 - 729
  • [9] Evaporation heat transfer coefficient and pressure drop of R-1233zd(E) in a brazed plate heat exchanger
    Lee, DongChan
    Kim, Dongwoo
    Park, Seonggi
    Lim, Junyub
    Kim, Yongchan
    [J]. APPLIED THERMAL ENGINEERING, 2018, 130 : 1147 - 1155
  • [10] Lee W.H, 1980, Multiph. Transp.: Fundam. Reactor Safety Appl, P407