Effect of Indenter Load on Vickers Microhardness and Indentation Depth of One Resin Composite

被引:0
|
作者
Price, Richard B. [1 ]
Sullivan, Braden [1 ]
机构
[1] Dalhousie Univ, Dept Dent Clin Sci, 5981 Univ Ave, Halifax, NS B3H 4R2, Canada
关键词
composite resin; polymerization; light-curing; hardness measurement; monomer conversion; indentation size effect; BULK-FILL RESIN; POLYMERIZATION SHRINKAGE; MECHANICAL-PROPERTIES; CURING CHARACTERISTICS; MARGINAL ADAPTATION; MONOMER CONVERSION; LIGHT; HARDNESS; CURE; SIZE;
D O I
10.3390/ma17246156
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The load and size of the indentation may affect the hardness value. This study investigated the effect of the indentation size on the microhardness of one resin-based composite (RBC). Metal molds 4 mm deep and 12 mm in diameter were filled with Tetric EvoCeram Bulk Fill (Ivoclar) and light-cured for 10 s using a broad-spectrum LED curing light. The Vickers microhardness and the degree of conversion (DC) at the top and bottom surfaces were measured 24 h later before and after polishing the RBC. The microhardness measurements were made using 50, 100, 300 and 1000-gf loads with the same 8 s dwell time. The DC was measured in the same region using mid FT-IR spectroscopy. Repeated measures analysis of variance tests were used to determine if the surface (top vs. bottom) or the indenter loads had a significant effect on the VH, or if polishing affected the VH and the DC (alpha = 0.05). It was found that the indenter load did not affect the Vickers hardness of the unpolished top surface (p = 0.759), the polished top surface (p = 0.374), or the polished bottom surface (p = 0.083) of the Tetric EvoCeram Bulk Fill. Increasing the indenter load did increase the VH of the unpolished surface at the bottom (p < 0.0001). Polishing increased the DC by 13.5% at the top and by 46.7% at the bottom surface.
引用
收藏
页数:13
相关论文
共 37 条
  • [31] Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units
    Barakah, Haifa
    SAUDI DENTAL JOURNAL, 2021, 33 (08) : 1035 - 1041
  • [32] Effect of aging and fiber-reinforcement on color stability, translucency, and microhardness of single-shade resin composites versus multi-shade resin composite
    Fidan, Muhammet
    Yagci, Ozhan
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (04) : 632 - 642
  • [33] Restoring Nonvital Premolars with Composite Resin Onlays: Effect of Different Fiber-reinforced Composite Layers on Marginal Adaptation and Fracture Load
    Monaco, Carlo
    Bortolotto, Tissiana
    Arena, Antonio
    Krejci, Ivo
    JOURNAL OF ADHESIVE DENTISTRY, 2015, 17 (06): : 567 - 574
  • [34] Effect of Composite Resin and Restorative Technique on Polymerization Shrinkage Stress, Cuspal Strain and Fracture Load of Weakened Premolars
    Martins, Lais Carvalho
    Sales Oliveira, Lais Rani
    Lourenco Braga, Stella Sueli
    Soares, Carlos Jose
    Versluis, Antheunis
    Borges, Gilberto Antonio
    Verissimo, Crisnicaw
    JOURNAL OF ADHESIVE DENTISTRY, 2020, 22 (05): : 503 - 514
  • [35] Effect of the Sample Preparation and Light-curing Unit on the Microhardness and Degree of Conversion of Bulk-fill Resin-based Composite Restorations
    Braga, S. S. L.
    Schettini, A. C. T.
    Carvalho, E. L. O.
    Shimokawa, C. A. K.
    Price, R. B.
    Soares, C. J.
    OPERATIVE DENTISTRY, 2022, 47 (02) : 163 - 172
  • [36] Caries-preventive effect of a one-time application of composite resin and glass ionomer sealants after 5 years
    Beiruti, N
    Frencken, JE
    van't Hof, MA
    Taifour, D
    Helderman, WHV
    CARIES RESEARCH, 2006, 40 (01) : 52 - 59
  • [37] Effect of volume fraction of cashew nut de-oiled husk biosilica on load-bearing properties of ramie fiber-reinforced vinyl ester resin composite
    Gayathri, N.
    Pragadish, N.
    Bright, B. Bradley
    Kumar, S. Santhosh
    BIOMASS CONVERSION AND BIOREFINERY, 2023, 14 (24) : 32219 - 32228