Label-Free Ultrasensitive Cholesterol Detection Based on SPR Optical Fiber Sensor

被引:1
|
作者
Zhang, Hongxin [1 ,2 ,3 ]
Li, Xuegang [1 ,2 ,3 ]
Zhou, Xue [1 ,2 ,3 ]
Zhang, Yanan [1 ,2 ,3 ]
机构
[1] Northeastern Univ, Foshan Grad Sch Innovat, Foshan 528311, Guangdong, Peoples R China
[2] Hebei Key Lab Micronano Precis Opt Sensing & Measu, Qinhuangdao 066004, Peoples R China
[3] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Optical fiber sensors; Optical surface waves; Sensitivity; Surface treatment; Coatings; Optical fibers; Refractive index; Probes; Carbon nanotubes; beta-cyclodextrin (beta-cd); carbon nanotubes (CNTs); cholesterol; fiber-optic sensor; surface plasmon resonance (SPR); BIOSENSOR;
D O I
10.1109/JSEN.2024.3489622
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A sensitivity-improved fiber-optic sensor based on surface plasmon resonance (SPR) is proposed, and a strategy [using polyacrylic acid (PAA) and chitosan] to fix carbon nanotubes (CNTs) on the probe to detect cholesterol is established. CNTs can improve the sensitivity of the sensor. The sensitivity of the sensor after coating with CNTs is 2437 nm/RIU, which increases by 65% compared with the uncoated sensor. $\beta $ -cyclodextrin ( $\beta $ -cd) can recognize cholesterol molecules. First, the traditional 11-mercaptoundecanoic acid (MUA) method was used to fix $\beta $ -cd on the sensor, and cholesterol sensitivity is 0.023 nm/nM in the range of 10-300 nM. Then, the Langmuir adsorption isotherm model was used to analyze the detection of cholesterol by the new method. Experiment results show that cholesterol sensitivity was 0.065 nm/nM at 10-400 nM (2.83 times than the MUA method), and the limit of quantification (LOQ) was 2.34 nM. In addition, the sensor has expanded detection range, improved the sensitivity of the sensor, and also has good stability and selectivity, paving the way for the future use of fiber sensors in cholesterol detection.
引用
收藏
页码:40972 / 40978
页数:7
相关论文
共 50 条
  • [21] Label-free detection of lysozyme in wines using an aptamer based biosensor and SPR detection
    Mihai, Luliana
    Vezeanu, Alis
    Polonschii, Cristina
    Albu, Camelia
    Radu, Gabriel-Lucian
    Vasilescu, Alina
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 198 - 204
  • [22] An Enhanced Bimetallic Optical Fiber SPR Biosensor Using Graphene Oxide for the Label-Free and Sensitive Detection of Human IgG
    Xu, Qiang
    Yin, Huiting
    Cui, Mei
    Huang, Renliang
    Su, Rongxin
    SENSORS, 2025, 25 (05)
  • [23] Label-free electrochemical immunoassay for ultrasensitive detection of norethindrone
    Zhang, Yong
    Du, Bin
    Wei, Qin
    Wu, Dan
    Li, He
    Ma, Hongmin
    Dai, Yuxue
    Li, Yuyang
    MONATSHEFTE FUR CHEMIE, 2014, 145 (01): : 155 - 160
  • [24] An electrochemical impedance sensor for the label-free ultrasensitive detection of interleukin-6 antigen
    Yang, Ting
    Wang, Shun
    Jin, Huile
    Bao, Weiwei
    Huang, Shaoming
    Wang, Jichang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 310 - 315
  • [25] Chitosan-nickel film based interferometric optical fiber sensor for label-free detection of histidine tagged proteins
    Ravikumar, Raghunandhan
    Chen, Li Han
    Jayaraman, Premkumar
    Poh, Chueh Loo
    Chan, Chi Chiu
    BIOSENSORS & BIOELECTRONICS, 2018, 99 : 578 - 585
  • [26] Sensitive and label-free liquid crystal-based optical sensor for the detection of malathion
    Pham Thi Kim Hong
    Jang, Chang-Hyun
    ANALYTICAL BIOCHEMISTRY, 2020, 593
  • [27] Capacitive biosensors for label-free and ultrasensitive detection of biomarkers
    Huang, Lei
    Zhang, Cheng
    Ye, Run
    Yan, Bin
    Zhou, Xiaojia
    Xu, Wenbo
    Guo, Jinhong
    TALANTA, 2024, 266
  • [28] Label-free electrochemical immunoassay for ultrasensitive detection of norethindrone
    Yong Zhang
    Bin Du
    Qin Wei
    Dan Wu
    He Li
    Hongmin Ma
    Yuxue Dai
    Yuyang Li
    Monatshefte für Chemie - Chemical Monthly, 2014, 145 : 155 - 160
  • [29] A Measurement Platform for Label-Free Detection of Biomolecules Based on a Novel Optical BioMEMS Sensor
    Marvi, Fahimeh
    Jafari, Kian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [30] Label-free SPR fiber microfluidic sensor with PDA-MA cross-linked lipase for specific detection of tributyrin
    Zhang, Hongxin
    Li, Xuegang
    Zhou, Xue
    Zhang, Yanan
    Zhao, Yong
    OPTICS AND LASER TECHNOLOGY, 2024, 176