Coordinated Control of Second-Order Harmonic Voltage and Current Fluctuations in Cascaded H-Bridge Inverter with Supercapacitor and DC-DC Stage at Variable Output Frequencies

被引:0
作者
Zhang, Ye [1 ,2 ]
Li, Zixin [1 ,2 ]
Gao, Fanqiang [1 ,2 ]
Zhang, Jinhao [1 ,2 ]
Zhao, Cong [1 ,2 ]
Li, Yaohua [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Key Lab High Dens Electromagnet Power & Syst, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Harmonic analysis; Fluctuations; Voltage control; Power harmonic filters; Capacitors; Voltage fluctuations; Inverters; Frequency control; Supercapacitors; Stress; Cascaded H-bridge inverter (CHBI); DC-DC current reduction; Second-order harmonic fluctuation; Variable frequencies; Proportional-integral-resonant; 2ND-HARMONIC CURRENT REDUCTION; CONTROL SCHEMES; CONVERTER;
D O I
10.30941/CESTEMS.2024.00038
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the cascaded H-bridge inverter (CHBI) with supercapacitor and dc-dc stage, inherent second-order harmonic power flows through each submodule (SM), causing fluctuations in both the dc-link voltage and the dc-dc current. There exist limitations in handling these fluctuations at variable output frequencies when employing proportional-integral (PI) control to the dc-dc stage. This paper aims to coordinately control these second-order harmonic voltage and current fluctuations in the CHBI. The presented method configures a specific second-order harmonic voltage reference, equipped with a maximum voltage fluctuation constraint and a suitable phase, for the dc-dc stage. A PI-resonant controller is used to track the configured reference. This allows for regulating the second-order harmonic fluctuation in the average dc-link voltage among the SMs within a certain value. Importantly, the second-order harmonic fluctuation in the dc-dc current can also be reduced. Simulation and experimental results demonstrate the effectiveness of the presented method.
引用
收藏
页码:481 / 492
页数:12
相关论文
共 26 条
[21]   Second-Harmonic Current Reduction for Two-Stage Inverter With Boost-Derived Front-End Converter: Control Schemes and Design Considerations [J].
Zhang, Li ;
Ruan, Xinbo ;
Ren, Xiaoyong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (07) :6361-6378
[22]  
[张力 Zhang Li], 2014, [电工技术学报, Transactions of China Electrotechnical Society], V29, P136
[23]   Coordinated Capacitor Voltage Balancing Method for Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage [J].
Zhang, Ye ;
Li, Zixin ;
Gao, Fanqiang ;
Zhao, Cong ;
Li, Yaohua .
CES TRANSACTIONS ON ELECTRICAL MACHINES AND SYSTEMS, 2024, 8 (02) :191-201
[24]   Coordinated Balancing Charging Strategy for Cascaded H-Bridge Inverter With Supercapacitor and DC-DC Stage [J].
Zhang, Ye ;
Li, Zixin ;
Gao, Fanqiang ;
Zhao, Cong ;
Li, Yaohua .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (07) :7262-7272
[25]   A Modified Hybrid Modulation Strategy for Suppressing DC Voltage Fluctuation of Cascaded H-Bridge Photovoltaic Inverter [J].
Zhao, Tao ;
Zhang, Xing ;
Mao, Wang ;
Wang, Fusheng ;
Xu, Jun ;
Gu, Yilei .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (05) :3932-3941
[26]  
Zhu G. P., 2013, Methods of Reducing Second Harmonic Current in the Front-end DC-DC Converter in Two-stage Inverter