Waste heat utilization: Energy and economic benefits from multi-ejector chiller sub-cooling R744 supermarket refrigeration systems

被引:1
作者
Sengupta, Ayan [1 ]
Gullo, Paride [2 ]
Khorshidi, Vahid [3 ]
Dasgupta, Mani Sankar [1 ]
机构
[1] BITS Pilani, Dept Mech Engn, Smart Bldg Lab, Pilani 333031, Rajasthan, India
[2] Univ Southern Denmark, Inst Mech & Elect Engn, Alsion 2, DK-6400 Sonderborg, Denmark
[3] Danfoss AS, Nordborgvej 81, DK-6430 Nordborg, Denmark
关键词
Refrigeration; R744; Supermarket; Ejector chiller; Subcooling; Parallel compression; CO2; PERFORMANCE; CYCLE;
D O I
10.1016/j.energy.2024.133657
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigated the energy and economic benefits of a novel sub-cooling technique using a heat-driven multi-ejector chiller (HDEC) in R744 supermarket refrigeration systems. Two configurations were evaluated: a conventional booster system with HDEC (CBEC) and a parallel compression system with HDEC (PCEC). Among various natural refrigerants, R717 was identified as most suitable for the HDEC. Various multi-ejector combinations were examined to assess the potential for waste heat utilization and energy savings in the R744 refrigeration system. The CBEC system provided effective operation only at ambient temperatures above 31 degrees C, whereas the PCEC system was effective above 24 degrees C. Performance of the proposed configurations were compared with a conventional R744 booster system (CB) and a parallel compression system (PC) both devoid of HDEC. The PCEC system showed improvements in the coefficient-of-performance ranging from 4.2 % to 23.9 % at ambient temperatures between 28 degrees C and 40 degrees C compared to the baselines. In various warm-climatic zones, including India, the Middle East, Thailand, and the USA, energy savings of approximately 2.1 %-9.5 % were observed compared to the PC system. Economic analysis indicated a reasonable payback period of 2.1-2.7 years for the additional investment required for deploying the PCEC system in Phoenix.
引用
收藏
页数:17
相关论文
共 38 条
  • [1] [Anonymous], 2024, THE 17 GOALS. Sustainable development
  • [2] [Anonymous], 2024, FLAMMABLE REFRIGERANTS and safety in automotive applications
  • [3] [Anonymous], 2024, Understanding refrigerant safety classification: a guide-stout energyenergy efficiency for buildings
  • [4] [Anonymous], 2024, Electricity prices around the world
  • [5] Energy and exergy analysis of a combined transcritical CO2 compression refrigeration and single effect H2O-LiBr vapour absorption system
    Arora, Akhilesh
    Singh, Nikhil Kumar
    Monga, Saksham
    Kumar, Omesh
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2011, 9 (04) : 453 - 471
  • [6] Incorporation of an organic Rankine cycle in a transcritical booster CO2 refrigeration system
    Bellos, Evangelos
    Tzivanidis, Christos
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (10) : 7964 - 7988
  • [7] Enhancing the performance of a CO2 refrigeration system with the use of an absorption chiller
    Bellos, Evangelos
    Tzivanidis, Christos
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 37 - 52
  • [8] Performance analysis of sub-cooled transcritical CO2 refrigeration system using vapour absorption refrigeration system and dew point evaporative cooling
    Beniwal, Ravi
    Tyagi, Himanshu
    [J]. ENERGY, 2024, 310
  • [9] Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives
    Chen, Jianyong
    Havtun, Hans
    Palm, Bjorn
    [J]. APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 182 - 191
  • [10] Experimental analysis of R744 parallel compression cycle
    Chesi, Andrea
    Esposito, Fabio
    Ferrara, Giovanni
    Ferrari, Lorenzo
    [J]. APPLIED ENERGY, 2014, 135 : 274 - 285