Based upon investigations reported herein, the major causes for the deterioration of rubber and plastics insulated submarine power cables have been established as water permeation and sulfide infection. An especially significant discovery was tht sulfide infection in conventional non-metallic sheathed submarine cables is inevitable wherever the surrounding water contains sulfate reducing bacteria. As a result of studies to reduce or preferably eliminate cable degradation om these environments, it was determined that the incorporation of a newly developed thermoplastic barrier was effictive in preventing such deterioration.
引用
收藏
相关论文
共 39 条
  • [1] A NEW METHOD FOR THE PREVENTION OF WATER AND SULFIDE PENETRATION AND DETERIORATION OF CROSS-LINKED POLYETHYLENE (XLP) INSULATED SUBMARINE POWER-CABLES
    FUKUDA, T
    IRIE, S
    FUJIKI, S
    HISATSUNE, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (06): : 2094 - 2101
  • [2] New Ways for Upgrading Thermoplastic PE and Cross-Linked PE-Insulated Power Cables.
    Eichmann, Dieter
    Schroeder, Gerhard
    Siemens-Zeitschrift, 1976, 50 (10): : 685 - 690
  • [3] DEVELOPMENT OF Y-SPLICES FOR 77 kV CROSS-LINKED POLYETHYLENE CABLES.
    Kawatsu, Motoo
    Kurihara, Hiroyuki
    Hara, Makoto
    Kobayashi, Masayuki
    Hitachi Review, 1981, 30 (03): : 139 - 142
  • [4] Quality Inspections of Cross-linked Polyethylene-insulated Cables by Impulse Test
    Woschitz, R.
    Panosch, W.
    Knollseisen, G.
    Sumereder, C.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2005, 122 (10): : 348 - 348
  • [5] Technological progress in accessories for high-voltage cross-linked polyethylene-insulated power cables
    Enokubo, Fumiaki
    Iwata, Zensuke
    Saito, Mitsugu
    Saito, Shigehiro
    Nakano, Takao
    Tanaka, Hiroshi
    Sakuma, Susumu
    Goto, Shin'ichi
    Furukawa Review, 1988, (06): : 98 - 107
  • [6] NEW WAYS FOR UPGRADING THERMOPLASTIC PE AND CROSS-LINKED PE INSULATED POWER-CABLES
    EICHMANN, D
    SCHRODER, G
    SIEMENS REVIEW, 1977, 44 (05): : 206 - 211
  • [7] TRANSMISSION OF ELECTRICITY USING HIGH-VOLTAGE CABLES INSULATED WITH CROSS-LINKED POLYETHYLENE
    SCHUPPE, WD
    KUNSTSTOFFE-PLASTICS, 1978, 25 (06): : 76 - 77
  • [8] Partial Discharge Patterns on Cross-Linked Polyethylene DC Power Cables
    Siregar, Mutiara Sofia
    Schichler, Uwe
    Woschitz, Rudolf
    Pirker, Alexander
    Suwarno
    2016 3RD CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2016, : 119 - 123
  • [9] ESTIMATION OF WATER-CONTENT IN CROSS-LINKED POLYETHYLENE INSULATED CABLES BY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    HARIDOSS, S
    TOBAZEON, R
    CRINE, JP
    APPLIED SPECTROSCOPY, 1988, 42 (01) : 186 - 188
  • [10] Radiation cross-linked cables. New types of the Dynax series made by Metallurgica Bresciana
    Metallurgica Bresciana, Italy
    Wire, 1 (33-34):