DEPENDENCE OF UNIFORM/NONUNIFORM FIELD TRANSFORMER OIL BREAKDOWN ON OIL COMPOSITION.

被引:0
|
作者
Hosticka, C.
机构
来源
| 1977年
关键词
ELECTRIC FIELD EFFECTS - Measurements - ELECTRIC INSULATION - Impulse Testing - ELECTRIC TRANSFORMERS - Oil Filled;
D O I
暂无
中图分类号
学科分类号
摘要
The 60-Hz and impulse breakdown characteristics of two oils, A and B, which differed markedly in needle-sphere (N-S) impulse strength were determined in uniform and divergent field geometries. Oil A, which had the higher N-S strength, was a commercial transformer oil, and Oil B was this same oil doped with anthracene. In the uniform field tests, the two oils had essentially equal bare electrode 60-Hz and impulse strengths and covered electrode 60-Hz strength. Oil B, the lower N-S strength oil, had a slightly higher covered electrode impulse strength. In weakly divergent fields, the 60-Hz breakdown and corona inception levels of Oil B were comparable or superior to those of Oil A. Impulse breakdown voltages were found to depend on oil composition and impulse polarity; however, these dependences varied with field divergence. The data suggest that the anthracene additive modified the divergent field breakdown initiation and streamer propagation processes in oil, and indicate a lack of correlation between the highly divergent field N-S test and the insulating characteristics of oils in uniform and weakly divergent fields.
引用
收藏
相关论文
共 50 条
  • [1] DEPENDENCE OF UNIFORM-NONUNIFORM FIELD TRANSFORMER OIL BREAKDOWN ON OIL BREAKDOWN AN OIL COMPOSITION
    HOSTICKA, C
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 326 - 326
  • [2] DEPENDENCE OF UNIFORM-NONUNIFORM FIELD TRANSFORMER OIL BREAKDOWN ON OIL COMPOSITION
    HOSTICKA, C
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1979, 14 (01): : 43 - 50
  • [3] Particle-initiated breakdown in a quasi-uniform field in transformer oil
    Carraz, F
    Rain, P
    Tobazeon, R
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (06) : 1052 - 1063
  • [4] Particle-initiated breakdown in a quasi-uniform field in transformer oil
    Wootton, RE
    Rain, P
    Tobazeon, R
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (03) : 457 - 459
  • [5] Breakdown Characteristics of Transformer Oil in a Uniform Field under Oscillating Impulse Voltage
    Li, Junhao
    Zhang, Liang
    Jin, Yuhui
    Yao, Xiu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 984 - 990
  • [6] Lightning Breakdown Voltage Evaluation of Palm Oil and Coconut Oil as Transformer Oil under Quasi-Uniform Field Conditions
    Katim, Nurul Izzatul Akma
    Ishak, Mohd Taufiq
    Amin, Nur Aqilah Mohamad
    Hamid, Mardhiah Hayati Abdul
    Ahmad, Khairol Amali
    Azis, Norhafiz
    ENERGIES, 2018, 11 (10)
  • [7] Impulse Breakdown Characteristics of Transformer Oil with Cellulose Particles in Quasi-Uniform Field
    Guo, Ruochen
    Wang, Zhen
    He, Cong
    Meng, Xuan
    Li, Junhao
    Han, Xutao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (01) : 107 - 115
  • [8] DEPENDENCE OF THE DIELECTRIC BREAKDOWN OF TRANSFORMER OIL ON ELECTRODE CONDITIONS
    HANCOX, R
    NATURE, 1956, 178 (4545) : 1305 - 1305
  • [9] Dependence of Breakdown Voltage of Transformer Oil on Temperature.
    Beletskii, Z.M.
    Ryzhenko, V.I.
    Topolyanskii, E.L.
    1600,
  • [10] INFLUENCE OF AN INSULATING FILM ON BREAKDOWN VOLTAGE OF TRANSFORMER OIL IN NONUNIFORM FIELDS
    EVANGELOU, CA
    ZAKY, AA
    MEGAHED, IY
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1975, 122 (02): : 225 - 226