Study on measure method of ferric on concentration in EDTA chemical cleaning

被引:0
|
作者
Fang, H.
Zhang, Z.
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In the process of EDTA chemical cleaning, it is indispensable to measure the ferric concentration. According to the method of cleaning instruction we measure on the spot, the content of iron is often obviously low. The problem set forth by the experiment is expatiated carefully, a measure method is fished out of addition of (HOCH2CH2)3N- Fe, a condition adaptive to the spot.
引用
收藏
页码:81 / 83
相关论文
共 50 条
  • [31] INFLUENCE OF THE CLEANING METHOD ON THE CHEMICAL BEHAVIOR OF HYDROPHILIC SILICON SURFACES
    LAMPERT, I
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (03) : C125 - C125
  • [32] Copper dissolution and electrochemical behavior in EDTA- and EDA-based solutions for steam generator chemical cleaning
    Hur, DH
    Choi, MS
    Lee, EH
    Kim, UC
    NUCLEAR ENGINEERING AND DESIGN, 2003, 224 (02) : 207 - 212
  • [33] SEM study of a low concentration EDTA solution on smear layer removal
    Perez, F
    Pourcel, N
    Peli, JF
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 276 - 276
  • [34] Study on coal chemical cleaning under mild conditions
    Ranliao Huaxue Xuebao, 5 (452-458):
  • [35] A new method to measure the carrier concentration of p-GaN
    Zhou Mei
    Zhao De-Gang
    ACTA PHYSICA SINICA, 2011, 60 (03)
  • [36] A new method to measure the concentration of argon–xenon gas mixture
    Jiajun Li
    Mengyun Guan
    Youyu Gan
    Peng Zhang
    Radiation Detection Technology and Methods, 2021, 5 : 280 - 283
  • [37] An UPLC-MSMS method to measure plasma homocysteine concentration
    Vayne, Caroline
    Deroche, Luc
    Drillaud, Nicolas
    Patin, Franck
    Bruno, Clement
    Maillot, Francois
    Labarthe, Francois
    Corcia, Philippe
    Bretagne, Isabelle Benz-de
    Andres, Christian R.
    Emond, Patrick
    Blasco, Helene
    ANNALES DE BIOLOGIE CLINIQUE, 2017, 75 (03) : 334 - 338
  • [38] Comparison between high concentration EDTA (24%) and low concentration EDTA (3%) with surfactant upon removal of smear layer after rotary instrumentation: A SEM study
    Daghustani, Mohsen
    Alhammadi, Ahmad
    Merdad, Khalid
    Ohlin, Johan
    Erhardt, Fredrik
    Ahlquist, Michael
    SWEDISH DENTAL JOURNAL, 2011, 35 (01) : 9 - 15
  • [39] Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments
    Kwon, Hyuk-chul
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2016, 15 (02): : 84 - 91
  • [40] OPERATIONAL CHEMICAL CLEANING OF ONCE-THROUGH BOILERS BY A SIMPLIFIED METHOD
    MAMET, AP
    ALEINIKO.GI
    TARATUTA, VA
    PESKOV, VA
    DROBOT, GK
    MARAKOV, NV
    COMBUSTION, 1973, 45 (05): : 21 - 24