Mass discrimination correction in multiple-collector plasma source mass spectrometry: An example using Cu and Zn isotopes

被引:0
|
作者
Archer, Corey [1 ,2 ]
Vance, Derek [1 ,2 ]
机构
[1] Department of Geology, Royal Holloway University of London, Egham, Surrey, TW20 0EX, United Kingdom
[2] Department of Earth Sciences, University of Bristol, Wills Memorial Building, Bristol, BS8 1RJ, United Kingdom
来源
Journal of Analytical Atomic Spectrometry | 2004年 / 19卷 / 05期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:656 / 665
相关论文
共 50 条
  • [21] In situ determination of sulfur isotopes in sulfur-rich materials by laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS)
    Mason, PRD
    Kosler, J
    de Hoog, JCM
    Sylvester, PJ
    Meffan-Main, S
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (02) : 177 - 186
  • [22] High-precision magnesium isotope analysis of geological and environmental reference materials by multiple-collector inductively coupled plasma mass spectrometry
    Gao, Ting
    Ke, Shan
    Li, Ruiying
    Meng, Xu'nan
    He, Yongsheng
    Liu, Chengshuai
    Wang, Yang
    Li, Zijian
    Zhu, Jian-Ming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (08) : 767 - 777
  • [23] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [24] High precision measurement of iron isotopes by plasma source mass spectrometry
    Belshaw, NS
    Zhu, XK
    Guo, Y
    O'Nions, RK
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 : 191 - 195
  • [25] Analysis of stable isotope ratios of Ba by double-spike standard-sample bracketing using multiple-collector inductively coupled plasma mass spectrometry
    Miyazaki, Takashi
    Kimura, Jun-Ichi
    Chang, Qing
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (03) : 483 - 490
  • [26] Investigation of the mass discrimination of multiple collector ICP-MS using neodymium isotopes and the generalised power law
    Wombacher, F
    Rehkämper, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) : 1371 - 1375
  • [28] High-precision Cu and Zn isotope analysis by plasma source mass spectrometry - Part 1. Spectral interferences and their correction
    Mason, TFD
    Weiss, DJ
    Horstwood, M
    Parrish, RR
    Russell, SS
    Mullane, E
    Coles, BJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) : 209 - 217
  • [29] The effect of instrumental mass bias on δ11B measurements:: a comparison between thermal ionisation mass spectrometry and multiple-collector ICP-MS
    Aggarwal, JK
    Mezger, K
    Pernicka, E
    Meixner, A
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 232 (03) : 259 - 263
  • [30] An evaluation on the extraction capability of anion exchange membranes for high-precision sulfur isotope measurement by multiple-collector inductively coupled plasma mass spectrometry
    Yang, Liu Willow
    Liu, Chenhui
    Yang, Tao
    RSC ADVANCES, 2019, 9 (54) : 31224 - 31232