Parameters Influencing Peak Localization Repeatability for X-ray Measurements-Use of Experiment Designs Technique

被引:0
|
作者
François, M. [1 ]
Bourniquel, B. [1 ]
Not, C. [2 ]
Guillen, R. [1 ]
Duval, C. [2 ]
机构
[1] Laboratoire d'Applications des Matériaux À la Mécanique (LAMM), IUT de Saint-Nazaire, Saint-Nazaire, France
[2] Aérospatiale, Centre Commun de Recherche Louis Blériot, Suresnes, France
关键词
D O I
10.1515/ijmr-2000-910513
中图分类号
学科分类号
摘要
The repeatability of peak position as a function of counting statistics has been studied for four localization methods: The parabola, the middle of chord, the centred centroid and the cross-correlation. Computer simulations of the diffraction peaks were performed to analyse, through an experiment design, the influence of six parameters: The peak to background ratio, the background slope, the peak breadth, shape and position and the acquisition range. The centred centroid gives a better repeatability than the other methods. Our results are also compared with the literature. © 2000 Carl Hanser Verlag. All rights reserved.
引用
收藏
页码:414 / 420
相关论文
共 50 条
  • [31] TECHNIQUE FOR ROUTINE PELVIMETRY WITH USE OF A SINGLE X-RAY FILM
    THOMS, H
    BILLINGS, WC
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 160 (06): : 448 - 451
  • [32] MEASUREMENTS OF HIGH-ALTITUDE X-RAY FLUX DURING ARAKS EXPERIMENT
    ROEDER, JL
    LEVERENZ, H
    SHELDON, WR
    BERING, EA
    BENBROOK, JR
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1977, 58 (08): : 724 - 724
  • [33] Magnetic and X-ray diagnostics for plasma position measurements in the ignition experiment Ignitor
    Bombarda, F.
    Alladio, F.
    Pizzicaroli, G.
    Licciulli, A.
    Fersini, M.
    Diso, D.
    Paulicelli, E.
    BURNING PLASMA DIAGNOSTICS, 2008, 988 : 434 - +
  • [34] Silicon drift detectors for the kaonic atom X-ray measurements in the SIDDHARTA experiment
    Ishiwatari, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 326 - 329
  • [35] A technique for the X-ray examination of crystal structures with many parameters.
    Bragg, WL
    West, J
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1928, 69 (1/2): : 118 - 148
  • [36] THE STACKING-FAULT ENERGY OF COPPER FROM X-RAY PEAK SHIFT MEASUREMENTS
    SHETTY, MN
    ZEITSCHRIFT FUR METALLKUNDE, 1982, 73 (11): : 689 - 691
  • [37] A TECHNIQUE FOR THE MEASUREMENT OF THE PEAK TUBE POTENTIAL OF X-RAY GENERATORS USING FLUORESCENCE X-RAYS
    SMITH, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 191 - 192
  • [38] Repeatability of facial soft tissue thickness measurements for forensic facial reconstruction using X-ray images
    Bulut, Ozgur
    Gungor, Kahraman
    Thiemann, Nicolle
    Hizliol, Ismail
    Gurcan, Safa
    Hekimoglu, Baki
    Kaya, Elif
    Ozdede, Melih
    Akay, Gulsun
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2017, 49 (02) : 134 - 141
  • [39] Preliminary experiments of Thomson scattering X-ray source: Measurements of electron beam's parameters and their influence on the X-ray performance
    Du, YC
    Huang, WH
    Tang, CX
    Hua, JF
    Cheng, C
    Du, TB
    Xia, B
    He, XZ
    Du, Q
    Zheng, SX
    Chen, HB
    Lin, YZ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 : 84 - 86
  • [40] USE OF CRYSTAL-MONOCHROMATOR WITH ANOMALOUS X-RAY TRANSMISSION FOR PRECISE MEASUREMENTS OF UNIT-CELL PARAMETERS
    KURBATOV, BA
    UMANSKII, MM
    ZUBENKO, VV
    KRISTALLOGRAFIYA, 1972, 17 (05): : 1058 - &