Measurement of the anisotropy parameter of nails in the wavelength range from 900 nm to 1600 nm

被引:0
作者
机构
[1] Ueno, Masanori
[2] Mashita, Yukari
[3] 1,Arimoto, Hidenobu
[4] Kakuta, Naoto
[5] Yamada, Yukio
来源
Ueno, M. (masa-nori@ymdlab.mce.uec.ac.ip) | / Institute of Electrical and Electronics Engineers Inc., 445 Hoes Lane / P.O. Box 1331, Piscataway, NJ 08855-1331, United States期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Measurement of the anisotropy parameter of nails in the wavelength range from 900 nm to 1600 nm
    Ueno, M
    Mashita, Y
    Arimoto, H
    Kakuta, N
    Yamada, Y
    2005 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, 2005, : 593 - 594
  • [2] STELLAR INTEGRATED FLUXES FOR 216 STARS IN THE WAVELENGTH RANGE 380NM-900NM
    PETFORD, AD
    BLACKWELL, DE
    BOOTH, AJ
    HADDOCK, DJ
    LEGGETT, SK
    MOUNTAIN, CM
    SELBY, MJ
    ARRIBAS, S
    ASTRONOMY & ASTROPHYSICS, 1988, 203 (02) : 341 - 347
  • [3] Antireflection optical coatings for the spectral range 400-700nm, 400-900nm and 800-1600nm
    Honciuc, G
    Singurel, G
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2004, 6 (04): : 1199 - 1205
  • [4] STELLAR INTEGRATED FLUXES IN THE WAVELENGTH RANGE 380 NM - 900 NM DERIVED FROM JOHNSON 13-COLOR PHOTOMETRY
    PETFORD, AD
    BLACKWELL, DE
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1989, 78 (03): : 511 - 517
  • [5] Key comparison EURAMET.PR-K2.a.2011-spectral responsivity in the range of 900 nm to 1600 nm
    van den Berg, Steven
    Dekker, Paul
    Harris, Subrena
    Goodman, Teresa
    Smid, Marek
    Szajna, Grzegorz
    Gran, Jarle
    Andersson, Anne
    Kallberg, Stefan
    Bazkir, Ozcan
    Meric, Seval
    METROLOGIA, 2020, 57 (1A)
  • [6] Goniometric Examination of Diffuse Reflectance of a Skin Phantom in the Wavelength Range from 400 to 1600 nm
    Kikuchi, Yota
    Nagahori, Seiki
    Suzuki, Hironori
    Jin, Takashi
    Nomura, Yasutomo
    ADVANCED BIOMEDICAL ENGINEERING, 2023, 12 : 108 - 116
  • [7] MEASUREMENT OF STELLAR INTEGRATED FLUX IN THE WAVELENGTH RANGE 370 NM-950 NM
    PETFORD, AD
    LEGGETT, SK
    BLACKWELL, DE
    BOOTH, AJ
    MOUNTAIN, CM
    SELBY, MJ
    ASTRONOMY & ASTROPHYSICS, 1985, 146 (01) : 195 - 198
  • [8] PICOSECOND PULSE GENERATION AND DETECTION IN THE WAVELENGTH RANGE 1200-1600 NM
    COTTER, D
    WHITE, KI
    OPTICS COMMUNICATIONS, 1984, 49 (03) : 205 - 209
  • [9] Final report on the key comparison CCPR-K2.a-2003: Spectral responsivity in the range of 900 nm to 1600 nm
    Brown, Steven W.
    Larason, Thomas C.
    Ohno, Yoshi
    METROLOGIA, 2010, 47
  • [10] Excited state absorption measurement in the 900-1250 nm wavelength range for bismuth-doped silicate fibers
    Yoo, Seongwoo
    Kalita, Mridu P.
    Nilsson, Johan
    Sahu, Jayanta
    OPTICS LETTERS, 2009, 34 (04) : 530 - 532