Dual-energy X-ray diagnostics

被引:0
|
作者
Coumans, J.J.H. [1 ]
机构
[1] Medical Systems Division, Philips NPB, Best, Netherlands
来源
Philips Technical Review | 1986年 / 42卷 / 8-9期
关键词
BIOMEDICAL ENGINEERING - Computerized Tomography - RADIOGRAPHY - X-Ray - X-RAYS - Scattering;
D O I
暂无
中图分类号
学科分类号
摘要
The X-ray attenuation coefficient of biological materials can be split into separate contributions due to Compton scattering and photoelectric absorption. The contributions are each the product of a known energy-dependent factor and an unknown material-dependent factor. If two X-ray exposures are made at different energies the material-dependent factors due to Compton scattering and to photoelectric absorption can be determined. This enables X-ray images entirely due to Compton scattering or to photoelectric absorption to be calculated. These images can be weighted by the energy-dependent factors and combined to give monoenergetic X-ray images. The contrasts between tissues can then be varied by varying the notional X-ray energy. A calibration procedure is necessary because the polyenergetic X-radiation becomes harder in the object. This procedure provides calibration coefficients for the material-dependent factors. A Philips CT scanner has been modified to supply alternate high-voltage and low-voltage pulses to the X-ray tube.
引用
收藏
页码:274 / 285
相关论文
共 50 条
  • [41] Dual-Energy X-Ray Absorptiometry for Quantification of Visceral Fat
    Kaul, Sanjiv
    Rothney, Megan P.
    Peters, Dawn M.
    Wacker, Wynn K.
    Davis, Cynthia E.
    Shapiro, Michael D.
    Ergun, David L.
    OBESITY, 2012, 20 (06) : 1313 - 1318
  • [42] CONFRONTING MORPHOMETRIC X-RAY RADIOGRAPHY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE DIAGNOSIS OF OSTEOPOROSIS
    Stefani, A.
    Desideri, G.
    Camerota, A.
    Carucci, A. C.
    Caporuscio, S.
    Canzoni, M.
    Raffaele, A.
    Sorgi, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S389 - S389
  • [43] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [44] Multiscale deformable registration for dual-energy x-ray imaging
    Gang, G. J.
    Varon, C. A.
    Kashani, H.
    Richard, S.
    Paul, N. S.
    Van Metter, R.
    Yorkston, J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (02) : 351 - 363
  • [45] CZT detector for dual-energy x-ray absorptiometry (DEXA)
    Wear, J
    Buchholz, M
    Payne, R
    Gorsuch, D
    Bisek, J
    Ergun, D
    Grosholz, J
    Falk, R
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 175 - 188
  • [46] Dual-energy X-ray absorptiometry in osteonecrosis of the femoral head
    Laroche, M
    Costa, L
    Bernard, J
    Puget, J
    Constantin, A
    Cantagrel, A
    Mazieres, B
    REVUE DU RHUMATISME, 1998, 65 (06): : 393 - 396
  • [47] Epicardial Fat Assessed by Dual-Energy X-Ray Absorptiometry
    Diano, D.
    Garzillo, G.
    Vicennati, V.
    Pizzi, C.
    Ferrari, F.
    Pasquali, R.
    Bazzocchi, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [48] The effect of room temperature on dual-energy X-ray absorptiometry
    N. L. Culton
    N. A. Pocock
    Osteoporosis International, 2003, 14 : 137 - 140
  • [49] The effect of room temperature on dual-energy X-ray absorptiometry
    Culton, NL
    Pocock, NA
    OSTEOPOROSIS INTERNATIONAL, 2003, 14 (02) : 137 - 140
  • [50] Clinical audit of a dual-energy X-ray absorptiometry service
    M. Au-Yeong
    S. van der Kamp
    M. J. McKenna
    Irish Journal of Medical Science, 2002, 171 (Suppl 5) : 25 - 25