Operating experience with a high-dust SCR plant in a lignite-fired 300 MW unit

被引:0
|
作者
Schoengrundner, W. [1 ]
Hiebler, J. [1 ]
Zierler, W. [1 ]
机构
[1] Oesterreichnische Draukraftwerke AG, Oesterreich, Germany
来源
VGB-Kraftwerkstechnik | 1995年 / 75卷 / 01期
关键词
Ammonia - Ammonium compounds - Catalysts - Equipment - Erosion - Fly ash - Monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
After more than 10 000 operating hours, the experience can be summarized as follows: The devices for NH4OH supply had to be improved. It seems to be advisable to monitor the reduction agent consequently. Comprehensive countermeasures had to be taken in order to solve catalyst problems (fly ash deposits, erosion). The gaseous NH3 slip was monitored by observing the NH3 content in the fly ash. The results achieved so far are plausible. The future development will be of interest, particularly with increased NH3 slip.
引用
收藏
页码:61 / 66
相关论文
共 25 条
  • [21] Two and a Half Years of Operating Experience with an SO3 Flue Gas Conditioning Plant on a 150 mw Unit.
    Junkers, G.
    VGB-Kraftwerkstechnik, 1983, 63 (07): : 599 - 606
  • [22] Study of Numerical Simulation and Experimental of Gas Flow Distribution of Electric Composite Filter Bag in 300MW Power Unit in Coal-fired Power Plant
    Dang Xiaoqing
    Hu Hongsheng
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [23] Development of a model for the optimization of catalyst exchange strategies on the basis of operating experience from the SCR-DENOX plant on unit 7 at Heilbronn Heating Power Station
    Schneider, G.
    Kapr, Th.
    Rueckold, M.
    VGB-Kraftwerkstechnik, 1995, 75 (01): : 43 - 53
  • [24] Energy-saving mechanism and parametric analysis of the high back-pressure heating process in a 300 MW coal-fired combined heat and power unit
    Chen, Heng
    Xiao, Yao
    Xu, Gang
    Xu, Jidong
    Yao, Xianhuai
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2019, 149 : 829 - 840
  • [25] Fault intelligent diagnosis for high-pressure feed-water heater system of a 300 MW coal-fired power unit based on improved BP neural network
    Ma, LY
    Gao, JQ
    Wang, BS
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1535 - 1539