SOME FEATURES OF STREAMER TUBE OPERATION.

被引:0
|
作者
Filatova, N.A. [1 ]
Golovatyuk, V.M. [1 ]
Guzik, Z. [1 ]
Kadyrov, R.B. [1 ]
Ryzhov, V.N. [1 ]
Sadovsky, A.B. [1 ]
Tsyganov, E.N. [1 ]
Tyapkin, I.A. [1 ]
Vodopianov, A.S. [1 ]
Zimin, V.I. [1 ]
Zinchenko, A.I. [1 ]
机构
[1] Joint Inst for Nuclear Research, Dubna, USSR, Joint Inst for Nuclear Research, Dubna, USSR
来源
关键词
PARTICLE DETECTORS - PHYSICS - High Energy;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of wire chambers with a metal cathode, operating in a self-quenching streamer mode, have been investigated. The influence of inaccuracies, introduced in the assembly of detectors, on their characteristics has been investigated. It is shown that the unstable operation of streamer tubes with a resistive cathode is a consequence of the graphite varnishing technology.
引用
收藏
页码:481 / 486
相关论文
共 50 条
  • [1] SOME FEATURES OF STREAMER TUBE OPERATION
    FILATOVA, NA
    GOLOVATYUK, VM
    GUZIK, Z
    KADYROV, RB
    RYZHOV, VN
    SADOVSKY, AB
    TSYGANOV, EN
    TYAPKIN, IA
    VODOPIANOV, AS
    ZIMIN, NI
    ZINCHENKO, AI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (03): : 481 - 486
  • [2] Investigation of a copper tube torn open in operation.
    Bach, C
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1907, 51 : 1667 - 1669
  • [3] Cleft-palate: Some pitfalls in operation.
    Addison, OL
    LANCET, 1925, 1 : 818 - 819
  • [4] Some deceptive abdominal conditions and the question of operation.
    Tubby, AH
    BRITISH MEDICAL JOURNAL, 1904, 1904 : 361 - 364
  • [5] A consideration of some cases of exophthalmic goitre treated by operation.
    Walton, AJ
    LANCET, 1914, 1 : 1387 - 1391
  • [6] Some Problems of Occupational Hygiene in Phosphorus Furnace Operation.
    Kozlovskii, V.A.
    Dardik, A.G.
    Meditsina Truda I Promyshlennaya Ekologiya, 1981, (12): : 3 - 7
  • [7] LARGE TURBOALTERNATORS - THEIR CONSTRUCTIONAL FEATURES COOLING AND HINTS FOR INITIAL OPERATION.
    Sahay, H.K.
    Irrigation and Power, 1979, 36 (01): : 59 - 66
  • [8] A streamer tube detector for operation at high rates in the CPLEAR experiment at CERN
    Bennet, JM
    Carroll, M
    Cawley, EL
    Dodgson, M
    Fry, JR
    Gabathuler, E
    Gamet, R
    Harrison, P
    Harrison, PF
    Haselden, AR
    Hayman, PJ
    King, D
    Maley, PD
    Sacks, LE
    Sanders, PM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (03): : 303 - 308
  • [9] An explosion at operation.
    不详
    LANCET, 1931, 1 : 1149 - 1149
  • [10] The shockless operation.
    Lockhart-Mummery, P
    LANCET, 1916, 2 : 249 - 249