DESIGN OF A BISMUTH GERMANATE ANTI-COMPTON SPECTROMETER AND ITS USE IN NUCLEAR SPECTROSCOPY.

被引:0
|
作者
Lieder, R.M.
Jaeger, H.
Neskakis, A.
Venkova, T.
Michel, C.
机构
关键词
GAMMA RAYS - Spectrum Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The design of an anti-Compton spectrometer consisting of a Ge detector and an asymmetric anti-Compton shield made of bismuth germanate is described. Its dimensions have been optimized by means of Monte Carlo calculations. The features predicted for this asymmetric anti-Compton shield are compared with those of symmetric ones. The design of a gamma - gamma coincidence spectrometer consisting of twelve anti-Compton spectrometers and a sum-energy and gamma -ray multiplicity filter is discussed. Results of neutron-sensitivity measurements for bismuth germanate and sodium iodide detectors are presented.