DESIGN OF A BISMUTH GERMANATE ANTI-COMPTON SPECTROMETER AND ITS USE IN NUCLEAR SPECTROSCOPY.

被引:0
|
作者
Lieder, R.M.
Jaeger, H.
Neskakis, A.
Venkova, T.
Michel, C.
机构
关键词
GAMMA RAYS - Spectrum Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The design of an anti-Compton spectrometer consisting of a Ge detector and an asymmetric anti-Compton shield made of bismuth germanate is described. Its dimensions have been optimized by means of Monte Carlo calculations. The features predicted for this asymmetric anti-Compton shield are compared with those of symmetric ones. The design of a gamma - gamma coincidence spectrometer consisting of twelve anti-Compton spectrometers and a sum-energy and gamma -ray multiplicity filter is discussed. Results of neutron-sensitivity measurements for bismuth germanate and sodium iodide detectors are presented.
引用
收藏
页码:363 / 370
相关论文
共 50 条
  • [21] ONLINE NEUTRON RESPONSE OF A GE-NAI(TL) ANTI-COMPTON SPECTROMETER
    MUKHERJEE, P
    SEN, P
    MUKHERJEE, I
    SAMANTA, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 251 (01): : 191 - 192
  • [22] Development of Anti-Compton LaBr3(Ce) Spectrometer for Measurement of Surrogate Reactions
    Makii, H.
    Ota, S.
    Ishii, T.
    Nishio, K.
    Nishinaka, I.
    Furutaka, K.
    Wakabayashi, Y.
    Chiba, S.
    Igashira, M.
    NUCLEAR DATA SHEETS, 2014, 119 : 361 - 364
  • [23] Experimental study of the integral background of a low-background anti-Compton HPGe γ-ray spectrometer
    Zhou Chunlin
    Xu Zhenhua
    Xu Congxue
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 649 - 653
  • [24] Calibration of a low-level anti-Compton underground gamma-spectrometer by experiment and Monte Carlo
    Sima, Octavian
    Osvath, Iolanda
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 109 - 113
  • [25] LU(N,GAMMA)-176 LU-177 REACTION STUDIED BY MEANS OF A PAIR AND ANTI-COMPTON SPECTROMETER
    MICHAUD, B
    SCHALLER, LA
    RIBORDY, L
    KERN, J
    HELVETICA PHYSICA ACTA, 1972, 45 (01): : 93 - &
  • [26] Resolution test technique and influencing factors analysis of a low-background anti-Compton HPGe γ-ray spectrometer
    Zhou Chunlin
    Xu Zhenhua
    Xu Congxue
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 571 - 575
  • [27] SIMULATION OF HTR-10 ANTI-COMPTON HPGE GAMMA-RAY SPECTROMETER WITH GEANT4
    Mao, Cui
    Liu, Yibao
    Zhang, Liguo
    Tong, Jiejuan
    Xia, Bing
    Yin, Zaizhe
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 5, 2018,
  • [28] USE OF BISMUTH-BACKINGS FOR IN-BEAM GAMMA SPECTROSCOPY.
    Zell, Karl Oskar
    Nuclear instruments and methods in physics research, 1984, 236 (03): : 655 - 657
  • [29] A Dual Scintillator - Dual Silicon Photodiode Detector Module for Intraoperative Gamma\Beta Probe and Portable Anti-Compton Spectrometer
    Rosenfeld, A. B.
    Lerch, M. L. F.
    Chan, M.
    Inwood, D.
    Takacs, G. J.
    Inwood, D.
    Lee, B.
    Gektin, A. F.
    Perevertaylo, V. L.
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 458 - 461
  • [30] An anti-Compton suppression Ge-telescope detection system for quality control of nuclear waste packages
    Agosteo, S
    Chabalier, B
    Para, AF
    Graf, U
    Huot, N
    Kekki, T
    Ravazzani, A
    Schillebeeckx, P
    Tanner, V
    Tiitta, A
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 555 - 558