CRYSTAL SPECTROMETER FOR MEASUREMENTS OF PIONIC X-RAYS.

被引:0
|
作者
Beer, W. [1 ]
Bos, K. [1 ]
De Chambrier, G. [1 ]
Giovanetti, K.L. [1 ]
Goudsmit, P.F.A. [1 ]
Grigoryev, B.V. [1 ]
Jeckelmann, B. [1 ]
Knecht, L. [1 ]
Kondurova, L.N. [1 ]
Langhans, J. [1 ]
Leisi, H.J. [1 ]
Levchenko, P.M. [1 ]
Marushenko, V.I. [1 ]
Mezentsev, A.F. [1 ]
Obermeier, H. [1 ]
机构
[1] Eidgenoessiche Technische, Hochschule, Inst for Intermediate, Energy Physics, Villigen, Switz, Eidgenoessiche Technische Hochschule, Inst for Intermediate Energy Physics, Villigen, Switz
来源
Nuclear instruments and methods in physics research | 1985年 / A238卷 / 2-3期
关键词
X-RAYS; -; Measurements;
D O I
暂无
中图分类号
学科分类号
摘要
A description is given of a bent-crystal spectrometer for pionic X-rays. The instrument is of the modified DuMond type and makes use of a combined pi -production-X-ray target. It is situated in a 20 mu A, 590 MeV proton beam at SIN. Combination of high mechanical precision and a laser interferometer system makes it possible to measure wavelength ratios with a precision of 1-2 parts per million.
引用
收藏
页码:365 / 380
相关论文
共 50 条
  • [11] Performances of the thin crystal spectrometer
    Kitamoto, S
    Ogata, H
    Horikawa, T
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 386 - 393
  • [12] The characteristics of the thin crystal spectrometer
    Kitamoto, S
    Ogata, H
    Horikawa, T
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 199 - 206
  • [13] Deconvolution of directly precipitating and trap-precipitating electrons in solar flare hard X-rays.: II.: Compton Gamma Ray Observatory data analysis
    Aschwanden, MJ
    Schwartz, RA
    Dennis, BR
    ASTROPHYSICAL JOURNAL, 1998, 502 (01) : 468 - 480
  • [14] New Solar Irradiance Measurements from the Miniature X-Ray Solar Spectrometer Cubesat
    Woods, Thomas N.
    Caspi, Amir
    Chamberlin, Phillip C.
    Jones, Andrew
    Kohnert, Richard
    Mason, James Paul
    Moore, Christopher S.
    Palo, Scott
    Rouleau, Colden
    Solomon, Stanley C.
    Machol, Janet
    Viereck, Rodney
    ASTROPHYSICAL JOURNAL, 2017, 835 (02)
  • [15] Curved crystal spectrometer for energy calibration and spectral characterization of mammographic x-ray sources
    Hudson, LT
    Deslattes, RD
    Henins, A
    Chantler, CT
    Kessler, EG
    Schweppe, JE
    MEDICAL PHYSICS, 1996, 23 (10) : 1659 - 1670
  • [16] Measurements regarding a combined therapy concept for ophthalmic tumors consisting of brachytherapy and x-rays
    Manke, H.
    Fluehs, D.
    Stroth, M.
    Bechrakis, N. E.
    Foerster, A. M. H.
    Albrecht, J.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (04):
  • [17] Comparison Between X-rays Absorption and Emission Spectroscopy Measurements on a Ceramic Envelop Lamp
    BrunoLAFITTE
    MichelAUBES
    GeorgesZISSIS
    Plasma Science and Technology, 2007, (06) : 732 - 735
  • [18] Fabrication of uniformly redundant arrays and Young's slits for coherence measurements in X-rays
    Moldovan, N
    Paterson, D
    Divan, R
    Mancini, DC
    Lin, J
    Nugent, KA
    McNulty, I
    DESIGN AND MICROFABRICATION OF NOVEL X-RAY OPTICS, 2002, 4783 : 165 - 175
  • [19] Comparison between x-rays absorption and emission spectroscopy measurements on a ceramic envelop lamp
    Lafitte, Bruno
    Aubes, Michel
    Zissis, Georges
    PLASMA SCIENCE & TECHNOLOGY, 2007, 9 (06) : 732 - 735
  • [20] Dynamical diffraction of X-rays in ADP single crystal under influence of temperature gradient
    Mirzoyan, V. Gh.
    Truni, K. G.
    Grigoryan, P. A.
    Gevorgyan, K. M.
    Dezfouli, M. Ghannad
    JOURNAL OF CONTEMPORARY PHYSICS-ARMENIAN ACADEMY OF SCIENCES, 2014, 49 (02) : 74 - 79