Material damping for lumped-parameter models of foundations

被引:0
|
作者
Meek, Jethro W. [1 ]
Wolf, John P. [1 ]
机构
[1] Holst Construction Co, Hamburg, Germany
关键词
Continuum mechanics - Damping - Mathematical models - Viscoelasticity;
D O I
暂无
中图分类号
学科分类号
摘要
In foundation dynamics two mechanisms of energy dissipation exist, wave radiation and material damping. Elastic continuum models of the soil capture only the radiation effect. To incorporate material damping, use is made of the fact that the dynamic-stiffness relationships of all elastic foundations may be simulated by discrete assemblages of springs, dashpots and masses. (Such lumped-parameter models are exact for simple cone models of the soil and approximate for more involved cases.) By application of the correspondence principle directly to the discrete elements of the lumped-parameter model, it is possible to introduce Voigt viscoelasticity. Each original spring is augmented by a dashpot, and each original dashpot is augmented by a mass, attached in a special way. Going a step further, more realistic non-linear-hysteretic damping is represented by replacing the augmenting dashpots and masses by frictional elements. The analysis, which is effected solely in the time domain, is illustrated by an example from earthquake engineering.
引用
收藏
页码:349 / 362
相关论文
共 50 条
  • [1] MATERIAL DAMPING FOR LUMPED-PARAMETER MODELS OF FOUNDATIONS
    MEEK, JW
    WOLF, JP
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1994, 23 (04): : 349 - 362
  • [2] Systematic lumped-parameter models for foundations based on polynomial-fraction approximation
    Wu, WH
    Lee, WH
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (07): : 1383 - 1412
  • [3] Lumped-parameter models for foundations base on Chevshev complex polynomials-fraction
    College of Civil Engineering, Nanjing University of Technology, Nanjing 210009, China
    Gongcheng Lixue, 2013, 3 (133-139+151):
  • [4] FREQUENCY-DEPENDENT DAMPING COEFFICIENTS IN LUMPED-PARAMETER MODELS OF HUMAN BEINGS
    MUKSIAN, R
    NASH, CD
    JOURNAL OF BIOMECHANICS, 1976, 9 (05) : 339 - 342
  • [5] Nested lumped-parameter models for foundation vibrations
    Wu, WH
    Lee, WH
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2004, 33 (09): : 1051 - 1058
  • [6] Assessment of lumped-parameter models for rigid footings
    Andersen, L.
    COMPUTERS & STRUCTURES, 2010, 88 (23-24) : 1333 - 1347
  • [7] RECEPTANCES OF LUMPED-PARAMETER SYSTEMS CONTAINING DISCRETE DAMPING SOURCES
    HAMMILL, WJ
    ANDREW, C
    JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1971, 13 (04): : 296 - &
  • [8] CONCEPTUAL AND LUMPED-PARAMETER MODELS OF GEOTHERMAL RESERVOIRS.
    Gudmundsson, Jon
    Bulletin. Geothermal Resources Council, 1987, 16 (05): : 11 - 22
  • [9] Augmented Ensemble Calibration of lumped-parameter building models
    Carlos Andrade-Cabrera
    William J. N. Turner
    Donal P. Finn
    Building Simulation, 2019, 12 : 207 - 230
  • [10] Sensitivity in Multiconductor Transmission Line Lumped-Parameter Models
    Brancik, Lubomir
    31ST INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING TSP 2008, 2008, : 71 - 74