There will be four calorimeters in the system. Two calorimeters will be for large sizes and two for small sizes. The four calorimeters will be servo controlled using a DEC Micro-11 computer with an IEEE-488 interface bus. Indicator lights will identify runs in progress and switches will record calorimeter lid openings. The data will be available on the console printout as well as being sent to the instrument control computer. System accuracy from 2 to 12 watts will be 0. 2 percent.
引用
收藏
页码:981 / 983
相关论文
共 50 条
  • [41] Animal calorimetry. I. Notice : Preliminary discussion.
    Hari, P
    BIOCHEMISCHE ZEITSCHRIFT, 1924, 152 : 445 - 455
  • [42] SPECIFIC HEAT OF FLUE CURED TOBACCO BY DIFFERENTIAL SCANNING CALORIMETRY.
    Chakrabarti, S.M.
    Johnson, W.H.
    Transactions of the American Society of Agricultural Engineers, 1972, 15 (05): : 928 - 931
  • [43] LARGE-AREA SILICON DETECTION IN HADRONIC SAMPLING CALORIMETRY.
    Pensotti, S.
    Rancoita, P.G.
    Seidman, A.
    Vismara, L.
    Zambelli, M.
    Nuclear instruments and methods in physics research, 1986, A257 (03): : 538 - 542
  • [44] CHIRAL RECOGNITION OF ENANTIOMERIC PEPTIDES IN WATER AT 25 degree C BY CALORIMETRY.
    Barone, G.
    Castronuovo, G.
    Elia, V.
    Giancola, C.
    Journal of thermal analysis, 1984, 30 (06): : 1367 - 1374
  • [45] Measuring the Dissociation Enthalpy of Hydrates or Carbonates by High-temperature Calorimetry.
    Mueller, F.
    Prasser, Ch.
    CFI Ceramic Forum International, 1986, 63 (1-2): : 21 - 28
  • [46] A simple respiration apparatus for determination of oxygen and carbon dioxide in indirect calorimetry.
    McClendon, JF
    Anderson, HC
    Steggerda, FR
    Conklin, C
    Whitaker, M
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1928, 77 (02) : 413 - 420
  • [47] Clinical calorimetry. XXXIV. Ketosis and the respiratory exchange in diabetes.
    Richardson, HB
    Ladd, WS
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1924, 58 (03) : 931 - 968
  • [48] Oxidation kinetics of bioactive milk lipids using differential scanning calorimetry.
    Cheng, S.
    Wei, L.
    Muthukumarappan, K.
    Martinez-Monteagudo, S.
    JOURNAL OF DAIRY SCIENCE, 2019, 102 : 38 - 38
  • [49] DETERMINATION OF MOISTURE TRANSITIONS IN CELLULOSIC MATERIALS USING DIFFERENTIAL SCANNING CALORIMETRY.
    Nelson, Robert A.
    1600, (21):
  • [50] Animal calorimetry. Twelfth paper. The influence of the ingestion of fat.
    Murlin, JR
    Lusk, G
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1915, 22 (01) : 15 - 41