Choice of the Test Voltage Level for the Lightning Withstand Impulse Voltage for Transformers with Direct Cable Entry.

被引:0
|
作者
Schopper, E.
Wenger, S.
机构
关键词
Compendex;
D O I
暂无
中图分类号
学科分类号
摘要
ELECTRIC TRANSFORMERS
引用
收藏
页码:397 / 401
相关论文
共 50 条
  • [41] Evaluation of Overshoot Rate of Lightning Impulse Withstand Voltage Test Waveform Based on New Base Curve Fitting Methods - Application to Practical Diverse Waveforms
    Ueta, Genyo
    Tsuboi, Toshihiro
    Okabe, Shigemitsu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) : 352 - 362
  • [42] EFFECT OF SURFACE DISCHARGES ON LIGHTNING IMPULSE BREAKDOWN VOLTAGE OF OIL-IMPREGNATED PRESSBOARD IN POWER TRANSFORMERS
    Tshivhilinge, M. M.
    Nyamupangedengu, C.
    SAIEE AFRICA RESEARCH JOURNAL, 2016, 107 (01): : 38 - 45
  • [43] Test on lighting impulse withstand voltage of the Three Gorges Right Bank 550 kV GIS substation
    Hu, Wei
    Chen, Yong
    Wan, Qi-Fa
    Yang, Peng-Cheng
    Cao, Jing
    Huo, Feng
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (04): : 883 - 887
  • [44] SIMULATIONS OF LIGHTNING IMPULSE RESIDUAL VOLTAGE TEST OF SURGE ARRESTERS IN MATLAB-SIMULINK
    Bhuyan, Kaveri
    Chatterjee, Saibal
    2015 1ST CONFERENCE ON POWER, DIELECTRIC AND ENERGY MANAGEMENT AT NERIST (ICPDEN), 2015,
  • [45] Worldwide comparison of lightning impulse voltage measuring systems at the 400-kV level
    Hallstrom, J.
    Aro, M.
    Bergman, A.
    Bovier-Lapierre, V.
    Garnacho, F.
    Juvik, J. I.
    Kiseliev, V.
    Hong, Z. Lian
    Lucas, W.
    Li, Y.
    Pykala, M. -L.
    Rungis, J.
    Schon, K.
    Truong, V. H.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 388 - 391
  • [46] The Application of Distributed Partial Discharge Synchronous Detection with Wireless Communication on HV Cable Withstand Voltage Test
    Chen, Min
    Zhou, Zhipeng
    Pan, Daren
    Su, Tianyu
    Cai, Shitin
    Lu, Jingjing
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 694 - 698
  • [47] Evaluation of Overshoot Rate of Lightning Impulse Withstand Voltage Test Waveform Based on New Base Curve Fitting Methods - Study by Assuming Waveforms Generated in an Actual Test Circuit -
    Ueta, Genyo
    Tsuboi, Toshihiro
    Okabe, Shigemitsu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (06) : 1912 - 1921
  • [48] A Physical Approach of the Test Voltage Function for Evaluation of the Impulse Parameters in Lightning Impulse Voltages with Superimposed Oscillations and Overshoots
    Diaz, Ricardo R.
    Segovia, Adan A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (05) : 2738 - 2746
  • [49] Voltage-time characteristics and related approximation formula for 6.6-kv solid-core-type insulator having higher lightning impulse withstand voltage
    Matsumoto, Satoshi
    Sato, Tomoyuki
    Koga, Yoshiyasu
    Yokoyama, Shigeru
    IEEJ Transactions on Power and Energy, 2014, 134 (03) : 224 - 229
  • [50] Effects of Corona Ring Design upon Impulse Voltage Withstand Level of 380 kV V-Strings
    Ilhan, Suat
    Ozdemir, Aydogan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1638 - 1646