Correlations between the basic parameters of the solidification process of the commercially pure Sn-Pb eutectic in a metal/water-cooled mold system. A device simulating unidirectional solidification was designed and constructed to enable the heat transfer coefficient across the metal/mold interface to be measured with confidence. The correlations established make it possible to control the solidification parameters through the heat transfer conditions in the system.