Extending particle characterization limits in wafer processing
被引:0
|
作者:
C. R. Brundle and Associates
论文数: 0引用数: 0
h-index: 0
C. R. Brundle and Associates
[1
]
机构:
来源:
MICRO
|
/
7卷
/
8pp期
关键词:
Aluminum - Auger electron spectroscopy - Contamination - Integrated circuit manufacture - Morphology - Photoluminescence - Scanning electron microscopy - Secondary ion mass spectrometry - Silica - X ray spectroscopy;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
As analytical tools are called on determine ever-smaller particle size, the use of a scanning electron microscope with energy-dispersive x-ray spectroscopy (SEM/EDS) becomes inadequate for ascertaining the origin of microparticles. Additional methods other than SEM/EDS are required, featuring improved surface sensitivity, low-z material capability, and some chemical identification capability. This paper presents a case study on a specific process-induced contamination problem - the recurring formation of small aluminum-containing spheres during metal etch - and gives practical illustrative examples where SED/EDS must be augmented by other techniques.