REDUCTION OF BACKGROUND SIGNAL IN BISMUTH GERMANATE SCINTILLATORS.

被引:0
|
作者
Lewis, Trevor A. [1 ]
机构
[1] CEGB, Berkeley, Engl, CEGB, Berkeley, Engl
来源
Nuclear instruments and methods in physics research | 1988年 / A264卷 / 2-3期
关键词
SCINTILLATION COUNTERS;
D O I
暂无
中图分类号
学科分类号
摘要
**2**0**7Bi has been identified in bismuth germanate scintillators. It is shown that not all bismuth contains isotope 207 and scintillators manufactured from inactive material have reduced background signals.
引用
收藏
页码:534 / 535
相关论文
共 50 条
  • [1] THE REDUCTION OF BACKGROUND SIGNAL IN BISMUTH-GERMANATE SCINTILLATORS
    LEWIS, TA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 264 (2-3): : 534 - 535
  • [2] EFFICIENCY OF 7.62 CM BISMUTH-GERMANATE SCINTILLATORS
    MOSS, CE
    TISSINGER, EW
    HAMM, ME
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (02): : 378 - 384
  • [3] DEPENDENCE OF THE SIGNAL-TO-NOISE RATIO ON THE RADIUS OF CYLINDRICAL SCINTILLATORS.
    Zav'yalkin, F.M.
    Zubkov, Yu.G.
    Osipov, S.P.
    The Soviet journal of nondestructive testing, 1984, 20 (11): : 719 - 722
  • [4] New organocerium nanoclay scintillators.
    Davis, NB
    Schnabel, RC
    Hagerman, ME
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U1067 - U1067
  • [5] BISMUTH GERMANATE SCINTILLATORS: APPLICATIONS IN NUCLEAR SAFEGUARDS AND HEALTH PHYSICS.
    Moss, C.E.
    Dowdy, E.J.
    Lucas, M.C.
    Nuclear instruments and methods in physics research, 1985, 242 (03): : 480 - 483
  • [6] TIMING MEASUREMENTS WITH BARIUM FLUORIDE SCINTILLATORS.
    Sperr, P.
    Nuclear instruments and methods in physics research, 1987, A254 (03): : 635 - 636
  • [7] SOME PROPERTIES OF SLOW PLASTIC SCINTILLATORS.
    Teh, K.M.
    Shapira, D.
    Burks, B.L.
    Varner, R.L.
    Blankenship, J.L.
    Ludwig, E.J.
    Fauber, R.E.
    Maguire, C.F.
    Nuclear instruments and methods in physics research, 1987, A254 (03): : 600 - 603
  • [8] BISMUTH-GERMANATE SCINTILLATORS - APPLICATIONS IN NUCLEAR SAFEGUARDS AND HEALTH-PHYSICS
    MOSS, CE
    DOWDY, EJ
    LUCAS, MC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 480 - 483
  • [9] EFFECT OF RADIATION ON THE LUMINESCENCE OF PLASTIC SCINTILLATORS.
    Kulinich, Yu.A.
    Rukavishnikov, V.G.
    Chineikin, M.T.
    1600, (17):
  • [10] THERMAL STABILIZATION OF THE OPTICAL CHARACTERISTICS OF PLASTIC SCINTILLATORS.
    Berezin, I.A.
    Gorbachev, V.M.
    Nazarov, V.V.
    Negina, V.R.
    Popov, V.N.
    Sten'gach, I.N.
    Uvarov, N.A.
    Instruments and experimental techniques New York, 1981, 24 (1 pt 1): : 52 - 54