A method of calculating the leaching rates is presented. The calculation is done by means of a finite-difference computer code that couples all of the processes relating to copper leaching, convective circulation, and the injection, dissolution, and consumption of oxygen. Results and processes are presented in graphical, tabular, and equation form.