ENTRAINED MIST COLLECTION IN PACKED BEDS.

被引:0
|
作者
Akagi, Y. [1 ]
Takahashi, T. [1 ]
机构
[1] Okayama Univ of Science, Dep of, Applied Chemistry, Okayama, Jpn, Okayama Univ of Science, Dep of Applied Chemistry, Okayama, Jpn
关键词
CHEMICAL EQUIPMENT - Packed Beds;
D O I
暂无
中图分类号
O6 [化学]; TQ [化学工业];
学科分类号
0703 ; 0817 ;
摘要
Mechanisms of collection of entrained mist by packed-bed with Raschig ring, spheres and wire meshes were investigated experimentally. The variations of amount of reentrained mist and drop size distribution in downstream with elevation were examined especially at higher gas velocity than reentraining velocity. The mist flow rates were measured by the isokinetic sampling method and calorimetry, and the drop size distribution were determined by the immersion method in which silicon oil was used.