An electrical impedance tomography microscope

被引:0
|
作者
Griffiths, H. [1 ]
Tucker, M.G. [2 ]
Sage, J. [2 ]
Herrenden-Harker, W.G. [2 ]
机构
[1] Department of Medical Physics and Bioengineering, University Hospital of Wales, Heath Park, Cardiff CF4 4XW, United Kingdom
[2] Department of Physics and Astronomy, University of Wales, College of Cardiff, The Parade, Cardiff CF2 3YB, United Kingdom
关键词
Electric impedance - Electric impedance measurement - Printed circuit boards - Electric impedance tomography;
D O I
暂无
中图分类号
学科分类号
摘要
A circular array of 16 electrodes has been constructed for use as an electrical impedance tomography (EIT) microscope. The electrodes were made from 60 μm diameter gold wires anchored to a printed circuit board. The internal diameter of the array was 0.9 mm giving a theoretical spatial resolution of about 100 μm. For EIT imaging, the array was connected to an imaging system operating at 82 kHz. Static images of conducting and insulating filaments (copper wire and human hair) in saline solution were obtained as well as dynamic imaging sequences of glass microspheres migrating through the array. The interelectrode impedance was typically 5 kΩ and the transimpedances ranged from 14 to 210 Ω. © 1996 IOP Publishing Ltd.
引用
收藏
相关论文
共 50 条
  • [41] A Review on Electrical Impedance Tomography Spectroscopy
    Leitzke, Juliana Padilha
    Zangl, Hubert
    SENSORS, 2020, 20 (18) : 1 - 19
  • [42] Possibilities of electrical impedance tomography in gynecology
    Trokhanova, O., V
    Chijova, Y. A.
    Okhapkin, M. B.
    Korjenevsky, A., V
    Tuykin, T. S.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [43] Resolution Guarantees in Electrical Impedance Tomography
    Harrach, Bastian
    Ullrich, Marcel
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (07) : 1513 - 1521
  • [44] Electrical impedance tomography for clinical application
    XU ShaoFeng
    SHI Yan
    CAI MaoLin
    QI HaiTao
    WANG YiXuan
    Science China(Technological Sciences), 2022, (06) : 1433 - 1434
  • [45] Electrical impedance tomography for clinical application
    ShaoFeng Xu
    Yan Shi
    MaoLin Cai
    HaiTao Qi
    YiXuan Wang
    Science China Technological Sciences, 2022, 65 : 1433 - 1434
  • [46] Design of multiplexer for electrical impedance tomography
    Cagan, Jan
    Rosler, Jakub
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (05) : 5755 - 5760
  • [47] SOURCE CONSISTENCY ELECTRICAL IMPEDANCE TOMOGRAPHY
    Zhang, Tingting
    Jang, Geuk Young
    Oh, Tong In
    Jeung, Kyung Woon
    Wi, Hun
    Woo, Eung Je
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2020, 80 (01) : 499 - 520
  • [48] Electrical impedance tomography with square sensor
    Zhang, Cao
    Wang, Huaxiang
    MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 792 - +
  • [49] Electrical Impedance Tomography for Hemodynamic Monitoring
    Leonhardt, Steffen
    Pikkemaat, Robert
    Stenqvist, Ola
    Lundin, Stefan
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 122 - 125
  • [50] A calculable sensor for electrical impedance tomography
    Cao, Zhang
    Wang, Huaxiang
    Yang, Wuqiang
    Yan, Yong
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 140 (02) : 156 - 161