Characterization of windows and filters for coherent X-ray beamlines

被引:0
|
作者
Suzuki, Yoshio
Momose, Atsushi
Sugiyama, Hiroshi
机构
来源
Journal of Synchrotron Radiation | 1998年 / 5卷 / 03期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Beryllium windows and graphite heat absorbers used in coherent X-ray beamlines must be optically flat. If the optical path through the window varies by more than λ/4, the X-ray wave front will be distorted after passing through the window, and the divergence of the X-ray beam may be increased. This reduces the beam coherence. Beryllium, graphite and Kapton films have been tested using ultra-small-angle X-ray scattering. Wave-front distortion was also directly observed by means of phase-contrast X-ray microradiography. The measured increase of angular divergence is about 4 μrad. The wave-front distortion is larger than 2π (optical path difference of λ). These are serious problems for utilizing coherent X-ray beams.
引用
收藏
页码:596 / 599
相关论文
共 50 条
  • [41] Beryllium windows for x-ray tubes
    Klug, HP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1941, 12 (03): : 155 - 156
  • [42] Beam Coherence and X-ray Windows
    Khounsary, Ali
    Lai, Barry
    Qian, Jun
    Khachatryan, Ruben
    Maj, Josef
    Huang, Xianrong
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS V, 2010, 7802
  • [43] Using X-ray computerized tomography for characterization of defects in cartridge filters
    Maschio, C
    de Arruda, ACF
    JOURNAL OF TESTING AND EVALUATION, 2002, 30 (01) : 85 - 88
  • [44] X-ray scatter characterization in dedicated breast CT with bowtie filters
    Kontson, Kimberly
    Jennings, Robert J.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [45] Scanning coherent x-ray microscopy as a tool for XFEL nanobeam characterization
    Schropp, Andreas
    Hoppe, Robert
    Patommel, Jens
    Seiboth, Frank
    Uhlen, Fredrik
    Vogt, Ulrich
    Lee, Hae Ja
    Nagler, Bob
    Galtier, Eric C.
    Zastrau, Ulf
    Arnold, Brice
    Heimann, Philip
    Hastings, Jerome B.
    Schroer, Christian G.
    X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS X, 2013, 8849
  • [46] Full optical characterization of coherent x-ray nanobeams by ptychographic imaging
    Hoenig, Susanne
    Hoppe, Robert
    Patommel, Jens
    Schropp, Andreas
    Stephan, Sandra
    Schoeder, Sebastian
    Burghammer, Manfred
    Schroer, Christian G.
    OPTICS EXPRESS, 2011, 19 (17): : 16324 - 16329
  • [47] Characterization of x-ray phase vortices by ptychographic coherent diffractive imaging
    Vila-Comamala, J.
    Sakdinawat, A.
    Guizar-Sicairos, M.
    OPTICS LETTERS, 2014, 39 (18) : 5281 - 5284
  • [48] X-Ray Lasers and Coherent X-Ray Sources: Development and Applications X Introduction
    Klisnick, Annie
    Menoni, Carmen S.
    X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS X, 2013, 8849
  • [49] Soft X-ray multilayers and filters
    Wang, Zhan-Shan
    Wu, Yong-Gang
    Tang, Wei-Xing
    Qin, Shu-Ji
    Zhou, Bin
    Chen, Ling-Yan
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2002, 14 (03): : 385 - 388
  • [50] Optics for coherent x-ray sources
    Pantell, RH
    Feinstein, J
    Cremer, JT
    Piestrup, MA
    Beguiristain, HR
    Gary, CK
    OPTICS FOR FOURTH-GENERATION X-RAY SOURCES, 2001, 4500 : 123 - 132