Biomechanical aspects on rehydrated freeze-dried human allograft dura mater tissues

被引:0
|
作者
机构
[1] Wolfinbarger Jr., Lloyd
[2] Zhang, Yongxing
[3] Adam, Bao-Ling T.
[4] Homsi, Diana
[5] Gates, Kevin
[6] Sutherland, Vicki
来源
Wolfinbarger Jr., Lloyd | 1600年 / John Wiley & Sons Inc, New York, NY, United States卷 / 05期
关键词
Biomechanics - Collagen - Failure (mechanical) - Hydration - Light polarization - Scanning electron microscopy - Stiffness - Tensile testing - Tissue;
D O I
暂无
中图分类号
学科分类号
摘要
Biomechanical properties of rehydrated freeze-dried human dura mater tissues were studied. Scanning electron and polarized light analysis indicated a multilayered distribution of collagen fibers in the dura mater tissue. Uniaxial tensile testing of 95 test strips permitted determination of average values for failure stress (6.65±0.14 MPa), failure strain (0.15±0.003), tangent modulus (69.50±1.29 MPa), elongation (0.56±0.01), and tangent stiffness (12.53±0.24 kN/m) of the dura mater tissue.