Measurements of long gauge blocks using a fringe-counting interferometer and subgauge blocks with lines

被引:0
|
作者
Natl Research Lab of Metrology, Ibaraki, Japan [1 ]
机构
来源
Metrologia | / 1卷 / 41-48期
关键词
Glass - Helium neon lasers - Optical variables measurement - Surfaces;
D O I
暂无
中图分类号
学科分类号
摘要
A new method for measuring long gauge blocks using a fringe-counting interferometer with a 633 nm wavelength-stabilized He-Ne laser is described. Two subgauge blocks, which have V-type graduation lines covered with glass plates, are optically contacted with both sides of a long gauge block. They are handled with bare hands and the surfaces of the glass plates are wiped with a paper towel after the optical wringing procedure. Using the National Research Laboratory of Metrology 2 m line standard automatic measuring machine, several gauge blocks up to 1 m long are measured with a repeatability less than 0,1 μm in standard deviation. A comparison between the lengths of gauge blocks measured by the new method and by the conventional excess fractions method is made. The results show that the length of gauge blocks up to 1 m can be determined with an expanded uncertainty U = 0,3 μm, corresponding to a level of confidence of about 95%.
引用
收藏
相关论文
共 50 条
  • [21] Low-coherence tandem interferometer for remote calibration of gauge blocks
    Hirai, A
    Matsumoto, H
    RECENT DEVELOPMENTS IN TRACEABLE DIMENSIONAL MEASUREMENTS II, 2003, 5190 : 54 - 61
  • [22] Advances in interferometric length measurements of short gauge blocks
    Titov, A
    Malinovsky, I
    Belaïdi, H
    França, RS
    Massone, CA
    METROLOGIA, 2000, 37 (02) : 155 - 164
  • [23] Linear and angular measurements - An interferometer for use with gauge blocks up to 1000 mm with laser and white-light sources
    Bolonin, A. A.
    Bolonin, Ar. A.
    Bolonina, G. A.
    MEASUREMENT TECHNIQUES, 2006, 49 (09) : 845 - 849
  • [24] HIGH-PRECISION CALIBRATION OF LONG GAUGE BLOCKS USING THE VACUUM WAVELENGTH COMPARATOR
    DARNEDDE, H
    METROLOGIA, 1992, 29 (05) : 349 - 359
  • [25] Automated calibration of multiple long gauge blocks using the KRISS linear measurement system
    Kim, Jong-Ahn
    Lee, Jae Yong
    Woo, Jae Heun
    Eom, Sung Hoon
    Kim, Myung Soon
    Kang, Chu-Shik
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (04)
  • [26] Experimental comparison of two methods for the measurement of long gauge blocks
    A. A. Bolonin
    Art. A. Bolonin
    G. A. Bolonina
    Measurement Techniques, 2007, 50 : 720 - 724
  • [27] Uncertainty of measurement in calibration of long gauge blocks by mechanical comparison
    Acko, B
    Godina, A
    MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 471 - 476
  • [28] Experimental comparison of two methods for the measurement of long gauge blocks
    Bolonin, A. A.
    Bolonin, Art. A.
    Bolonina, G. A.
    MEASUREMENT TECHNIQUES, 2007, 50 (07) : 720 - 724
  • [30] PHASE-SHIFTING INTERFEROMETRY WITH A COUPLED INTERFEROMETER - APPLICATION TO OPTICAL ROUGHNESS OF GAUGE BLOCKS
    ISHIKAWA, S
    BONSCH, G
    BOHME, H
    OPTIK, 1992, 91 (03): : 103 - 108