Measurement for hemispherical emissivity of polished pure gold

被引:0
|
作者
Guo, Xinzhang [1 ]
He, Zinian [1 ]
机构
[1] Beijing Solar Energy Research Inst, Beijing, China
来源
关键词
Heat Transfer--Measurements - Radiation Effects--Measurements;
D O I
暂无
中图分类号
TK1 [热力工程、热机];
学科分类号
080702 ;
摘要
The measurement for hemispherical emissivity of polished pure gold at 60-300°C is reported. The influence of ambient temperature on the measuring value of the emissivity is discussed. Although the temperature difference between the cooling temperature and ambient temperature is quite large, the error of the measuring value of the emissivity is small. Therefore the emissivity can be measured by using tap water or a slightly cooled medium instead of liquid nitrogen coolant.
引用
收藏
页码:200 / 202
相关论文
共 50 条
  • [41] Method for measurement of the hemispherical/hemispherical reflectance of photovoltaic devices
    Parretta, A
    Yakubu, H
    Ferrazza, F
    OPTICS COMMUNICATIONS, 2001, 194 (1-3) : 17 - 32
  • [42] Emissivity measurement comparison
    Saxton, PC
    Moran, AL
    Rutledge, SK
    AMERICAN CERAMIC SOCIETY BULLETIN, 1999, 78 (10): : 55 - 58
  • [43] SPECTRAL EMISSIVITY MEASUREMENT
    DOMINGUEZ, KS
    WYNNYCKYJ, JR
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1989, 32 (08) : 1575 - 1580
  • [44] EMISSIVITY AND TEMPERATURE MEASUREMENT
    QUINN, TJ
    REVUE INTERNATIONALE DES HAUTES TEMPERATURES ET DES REFRACTAIRES, 1970, 7 (03): : 180 - +
  • [45] Spectral emissivity, hemispherical total emissivity, and constant pressure heat capacity of liquid vanadium measured by an electrostatic levitator
    Ishikawa, Takehiko
    Koyama, Chihiro
    Nakata, Yui
    Watanabe, Yuki
    Paradis, Paul-Francois
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2021, 163 (163):
  • [46] DETERMINATION OF TOTAL HEMISPHERICAL EMISSIVITY FROM 2 MEASURED VALUES OF TOTAL EMISSIVITY AT 3 DEGREES AND 45 DEGREES
    LOHRENGE.J
    TINGWALD.C
    OPTIK, 1970, 31 (05): : 404 - &
  • [47] VALIDITY OF KIRCHHOFF'S LAW FOR MEASURING THE TOTAL HEMISPHERICAL EMISSIVITY.
    Cheng, Shu Xia
    Ge, Xin Shi
    1600, (16):
  • [48] ADSORBATE-INDUCED CHANGE IN THE TOTAL HEMISPHERICAL EMISSIVITY OF W(100)
    WOJCIK, LA
    SIEVERS, AJ
    GRAHAM, GW
    RHODIN, TN
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (01) : 149 - 155
  • [49] Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements
    Monchau, Jean-Pierre
    Hameury, Jacques
    Ausset, Patrick
    Hay, Bruno
    Ibos, Laurent
    Candau, Yves
    HEAT AND MASS TRANSFER, 2018, 54 (05) : 1415 - 1425
  • [50] Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements
    Jean-Pierre Monchau
    Jacques Hameury
    Patrick Ausset
    Bruno Hay
    Laurent Ibos
    Yves Candau
    Heat and Mass Transfer, 2018, 54 : 1415 - 1425