CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems

被引:0
|
作者
Soreq NRC, 81800 Yavne, Israel [1 ]
机构
来源
关键词
Cameras - Carrier mobility - Gamma rays - Hole traps - Medical imaging;
D O I
暂无
中图分类号
学科分类号
摘要
CdTe and CdZnTe X-ray and gamma ray detectors in the form of single elements or as segmented monolithic detectors have been shown to be useful in medical and industrial imaging systems. These detectors possess inherently better energy resolution than scintillators coupled to either photodiodes or photomultipliers, and together with application specific integrated circuits they lead to compact imaging systems of enhanced spatial resolution and better contrast resolution. Photopeak efficiencies of these detectors is greatly affected by a relatively low hole mobility-lifetime product. Utilizing these detectors as highly efficient good spectrometers, demands use of techniques to improve their charge collection properties, i.e., correct for variations in charge losses at different depths of interaction in the detector. The corrections for the large hole trapping are made either by applying electronic techniques or by fabricating detector or electrical contacts configurations which differ from the commonly used planar detectors. The following review paper is divided into three parts: The first part discusses detector contact configurations for enhancing photopeak efficiencies and the single carrier collection approach which leads to improved energy resolutions and photopeak efficiencies at high gamma ray energies. The second part demonstrates excellent spectroscopic results using thick CdZnTe segmented monolithic pad and strip detectors showing energy resolutions less than 2% FWHM at 356 keV gamma rays. The third part discusses advantages and disadvantages of CdTe and CdZnTe detectors in imaging systems and describes new developments for medical diagnostics imaging systems.
引用
收藏
相关论文
共 50 条
  • [41] Contrast resolution study of CdZnTe detectors for medical imaging
    Pillai, B
    Giakos, GC
    Dasgupta, A
    Chowdhury, S
    Vedantham, S
    Ghotra, P
    Odogba, J
    VegaLozada, V
    Guntupalli, R
    Suryanarayanan, S
    Endorf, RJ
    Passalaqua, A
    Davros, WJ
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 451 - 458
  • [42] A new fabrication technique of CdTe strip detectors for gamma-ray imaging and spectroscopy
    Niraula, M
    Nakamura, A
    Aoki, T
    Tomita, Y
    Hatanaka, Y
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2002, 229 (02): : 1103 - 1107
  • [43] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [44] CdTe and CdZnTe detectors behavior in X-ray computed tomography conditions
    Ricq, S
    Glasser, F
    Garcin, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 45 - 52
  • [45] Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications
    Del Sordo, Stefano
    Abbene, Leonardo
    Caroli, Ezio
    Mancini, Anna Maria
    Zappettini, Andrea
    Ubertini, Pietro
    SENSORS, 2009, 9 (05) : 3491 - 3526
  • [46] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2434 - 2438
  • [47] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1292 - 1296
  • [48] IMPROVEMENTS IN MANUFACTURE OF CDTE GAMMA-RAY DETECTORS
    BRELANT, S
    ELLIOTT, M
    ENTINE, G
    HSU, S
    REVUE DE PHYSIQUE APPLIQUEE, 1977, 12 (02): : 141 - 146
  • [49] CdZnTe and CdTe materials for X-ray and gamma ray radiation detector applications
    Szeles, C
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2004, 241 (03): : 783 - 790
  • [50] CdTe-based Schottky diode X-ray detectors for medical imaging
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Kosyachenko, L. A.
    Maslyanchuk, O. L.
    Sklyarchuk, V. M.
    Grushko, E. V.
    Aoki, T.
    8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2008, 7008