110 kV Network Short-Circuit Test in the Voitsberg Steam Power Station.

被引:0
|
作者
Fischer, H. [1 ]
Katter, M. [1 ]
Mader, O. [1 ]
Roth, D.H. [1 ]
Taumberger, H. [1 ]
Urabl, E. [1 ]
机构
[1] Oesterreichische Draukraftwerke AG, Klagenfurt, Austria, Oesterreichische Draukraftwerke AG, Klagenfurt, Austria
关键词
ELECTRIC FAULT CURRENTS - Short Circuit Currents - ELECTRIC POWER SYSTEMS - Testing - ELECTRIC SWITCHGEAR;
D O I
暂无
中图分类号
学科分类号
摘要
The Voitsberg 3 thermal power station, having a rated capacity of 330 MW,. feeds the Styrian 110 kv systems. The operation of such a large unit output on a 110 kv system with a maximum short-circuit power of 5 GVA calls for special protections to maintain turbo set and network stability in the case of nearby three-pole short circuits. The good functioning of all the line, busbar and generating unit protections and of the Voitsberg 3 station auxiliaries was tested by means of an induced nearby three-pole short-circuit on the Voitsberg 110 kv busbar. The test has shown that given accurate test planning and adequate precautions in the 110 kv switchgear, at the protections and on the 110 kv network, it is possible to carry out a network short-circuit test without incurring undue risks.
引用
收藏
页码:493 / 496
相关论文
共 50 条
  • [41] Investigation on the degradation indicators of short-circuit tests in 1.2 kV SiC MOSFET power modules
    Du, H.
    Reigosa, P. D.
    Iannuzzo, F.
    Ceccarelli, L.
    MICROELECTRONICS RELIABILITY, 2018, 88-90 : 661 - 665
  • [42] An optimization algorithm for short-circuit current limitation of 500 kV power Grid by adjusting power grid configuration
    Zhang, Yongkang
    Cai, Zexiang
    Li, Aimin
    Xu, Min
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (22): : 34 - 39
  • [43] RESEARCH STATION POWER TEST CIRCUIT
    不详
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1967, 19 (24): : 701 - &
  • [44] Asymmetrical short-circuit of 20 kV medium voltage feeders
    Waluyo
    Arfianto, Teguh
    Iqbally, Muhammad
    EEA - Electrotehnica, Electronica, Automatica, 2017, 65 (03): : 97 - 105
  • [45] Transients in a 20 kV Network Due to Single-Phase Short-Circuit Faults in 220 kV Cable Lines
    Maiorov A.V.
    Chelaznov A.A.
    Maiorov, A.V. (info@rosseti.ru), 1600, Springer (54): : 424 - 428
  • [46] VIBRATION PROBLEMS DUE TO LOW FREQUENCY NOISE FROM A STEAM POWER STATION.
    Proc Int Conf Noise Control Eng, 1600, (895-898):
  • [47] INVESTIGATING SEPARATION OF STEAM AS APPLIED TO THE DRUM-SEPARATORS OF A NUCLEAR POWER STATION.
    Kozlov, Yu.V.
    Ryabov, G.A.
    Thermal Engineering (English translation of Teploenergetika), 1987, 34 (04): : 181 - 184
  • [48] The transformer short-circuit test and the high power laboratory in China - the past, present, and future
    He, YY
    Wang, MS
    Proceedings of the World Engineers' Convention 2004, Vol G, Ecological and Green Manufacturing, 2004, : 108 - 115
  • [49] Analysis and Research on Short-circuit Capability of Transformer in Power System Series Compensation Test
    Yang, Lei
    He, Peng
    Xiang, Chuan
    He, Xin
    Xiao, Can
    Chang, Chang
    Zhang, Dan
    Huang, Run
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1393 - 1398
  • [50] The transformer short-circuit test and the high power laboratory in China - the past, present, and future
    He, YY
    Wang, MS
    IEEE ELECTRICAL INSULATION MAGAZINE, 2004, 20 (01) : 14 - 19