110 kV Network Short-Circuit Test in the Voitsberg Steam Power Station.

被引:0
|
作者
Fischer, H. [1 ]
Katter, M. [1 ]
Mader, O. [1 ]
Roth, D.H. [1 ]
Taumberger, H. [1 ]
Urabl, E. [1 ]
机构
[1] Oesterreichische Draukraftwerke AG, Klagenfurt, Austria, Oesterreichische Draukraftwerke AG, Klagenfurt, Austria
关键词
ELECTRIC FAULT CURRENTS - Short Circuit Currents - ELECTRIC POWER SYSTEMS - Testing - ELECTRIC SWITCHGEAR;
D O I
暂无
中图分类号
学科分类号
摘要
The Voitsberg 3 thermal power station, having a rated capacity of 330 MW,. feeds the Styrian 110 kv systems. The operation of such a large unit output on a 110 kv system with a maximum short-circuit power of 5 GVA calls for special protections to maintain turbo set and network stability in the case of nearby three-pole short circuits. The good functioning of all the line, busbar and generating unit protections and of the Voitsberg 3 station auxiliaries was tested by means of an induced nearby three-pole short-circuit on the Voitsberg 110 kv busbar. The test has shown that given accurate test planning and adequate precautions in the 110 kv switchgear, at the protections and on the 110 kv network, it is possible to carry out a network short-circuit test without incurring undue risks.
引用
收藏
页码:493 / 496
相关论文
共 50 条
  • [21] Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
    Lisewski, Tomasz
    Luszcz, Jaroslaw
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 360 - 363
  • [22] Limiting Method of First Peak of Short-Circuit Current of 110kV Variable Impedance Transformer
    Ma K.
    Wang S.
    Yao X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 : 723 - 729and745
  • [23] Systematized short-circuit analysis of a 2 x 25 kV electric traction network
    Chen, TH
    Hsu, YF
    ELECTRIC POWER SYSTEMS RESEARCH, 1998, 47 (02) : 133 - 142
  • [24] Short-circuit Ruggedness Assessment of a 1.2 kV/180 A SiC MOSFET Power Module
    Ionita, Claudiu
    Nawaz, Muhammad
    Ilves, Kalle
    Iannuzzo, Francesco
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 1982 - 1987
  • [25] Analysis of Fault Recorder Data for Short-Circuit Current in a 500kV Busbar Short-Circuit Accident
    Cao, Wei
    Wang, Yong-sheng
    Liu, Bei
    Wang, Wei
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 1290 - +
  • [26] DISTRIBUTION OF THERMAL RESISTANCES IN FEEDWATER HEATERS OF A MODERN STEAM POWER STATION.
    Wadhawan, A.L.
    Singh, Gajendra
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1985, 65 (pt 3-4): : 109 - 116
  • [27] Oxygen concentration measurements in the receiving water, cooling water circuit and wastewater of the Voitsberg power station
    Ebersold, W.
    1977, 30 (06): : 300 - 307
  • [28] Thermal effect on electric power network components under short-circuit currents
    Polykrati, AD
    Karagiannopoulos, CG
    Bourkas, PD
    ELECTRIC POWER SYSTEMS RESEARCH, 2004, 72 (03) : 261 - 267
  • [29] MAXIMUM PARTIAL SHORT-CIRCUIT CURRENTS OF POWER-STATION UNITS WITHOUT TAP CHANGER
    OEDING, D
    WAIDER, G
    ETZ ARCHIV, 1988, 10 (06): : 173 - 180
  • [30] The broadband frequency characteristics of major equipment in the ±800 kV converter station and their influences to the short-circuit fault transient
    Zhang, Xiao
    Yu, Zhanqing
    He, Jinliang
    Wang, Yunchao
    Zeng, Rong
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 147 : 302 - 309