Automatically Disinfectable Air Cooler for Air Conditioning Plants in Hospitals.

被引:0
|
作者
Gruen, Ludwig
Pitz, Norbert
机构
来源
HLH Heizung Luftung/Klima Haustechnik | 1976年 / 27卷 / 09期
关键词
AIR CONDITIONING - Thermal Load - BIOMEDICAL ENGINEERING;
D O I
暂无
中图分类号
学科分类号
摘要
Surface coolers belong, owing to the formation of condenser water and to the secondary growth of bacteria, to the hygienically weak spots of the air conditioning plant. Tests are described on a newly developed surface cooler at which a secure disinfection takes place on a thermal way at 130 degree C during 30 min without any essential operational disturbance and without expenditure of work.
引用
收藏
页码:314 / 316
相关论文
共 50 条
  • [1] Return Air Circulation in Air Conditioning Installations for Hospitals.
    Rakoczy, T.
    Ki Klima Kaelte Heizung, 1984, 12 (01): : 39 - 41
  • [2] Air conditioning fresh air unit with solar air collector and evaporative cooler
    Jiang, Ping
    Lin, Xilong
    2020 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, PTS 1-5, 2020, 546
  • [3] The transfer of diphtheria bacteria through the air in hospitals.
    Herrmann, W
    Putz, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1942, 68 : 1101 - 1104
  • [4] Cooling and Dehumidification Capacity Chart of Surface Air Cooler in Air Conditioning
    Song, Xu
    Zhu, Tong
    Zhuang, Dijun
    Wang, Chunsheng
    Yao, Bo
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2014 - 2020
  • [5] OPTIMIZATION OF AIR-CONDITIONING AIR-COOLER INSTALLATION PARAMETERS IN MINES
    SEMESHKO, EG
    TSEITLIN, YA
    SOVIET MINING SCIENCE USSR, 1990, 26 (05): : 460 - 465
  • [6] PRACTICE OF AIR-CONDITIONING IN HOSPITALS
    WINTER, J
    ARBEITSMEDIZIN SOZIALMEDIZIN PRAVENTIVMEDIZIN, 1982, 17 (04): : 84 - 84
  • [7] The effect of duct design in the air conditioning plants on air quality
    Sacchi, E
    VENTILATION AND INDOOR AIR QUALITY IN HOSPITALS, 1996, 11 : 283 - 296
  • [8] Air conditioning apparatus for dry wind testing of air plants
    Votschal, AE
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1939, 24 : 396 - 399
  • [9] HYGIENIC ASPECTS OF AIR HUMIDIFICATION IN AIR-CONDITIONING PLANTS
    WANNER, HU
    WIRZ, M
    SOZIAL-UND PRAVENTIVMEDIZIN, 1974, 19 (5-6): : 351 - 356
  • [10] Air Conditioning in Future Special Hospitals (Biotrone).
    Ranscht-Froemsdorff, Werner
    Klima & Kaelte Ingenieur, 1977, 5 (04): : 139 - 146