SCOPE TRIGGER SYSTEM EASES HIGH-SPEED LOGIC DESIGN.

被引:0
|
作者
Evel, Ed [1 ]
机构
[1] Hewlett-Packard Co, Hewlett-Packard Co
来源
New Electronics | 1984年 / 17卷 / 21期
关键词
ELECTRONIC CIRCUITS; COMPARATOR - LOGIC CIRCUITS; EMITTER COUPLED - LOGIC DEVICES - Threshold Elements - OSCILLOSCOPES; CATHODE RAY;
D O I
暂无
中图分类号
学科分类号
摘要
The increased usage of new high-speed logic families, such as ECL 10KH and 100K, has greatly increased the demands placed on the test equipment needed for the design, development, and troubleshooting of systems designed with such logic. A high bandwidth oscilloscope is essential for evaluation and troubleshooting such circuits. High bandwidth in the HP54100 A/D is achieved using a random-repetitive sampling technique where a 1GHz sampler is run continuously at a 40 megasample/second digitizing rate. The sampler output is converted and stored in digital memory for later display.