STRENGTH AND FAILURE MODES IN NOTCHED PULTRUDED ROD TENSION SPECIMENS.

被引:0
|
作者
Mallick, P.K.
Little, R.E.
Haupt, E.
机构
来源
关键词
Failure analysis - MATERIALS TESTING - Tensile Tests - Stresses;
D O I
10.1520/ctr10250j
中图分类号
学科分类号
摘要
Failure mode in a notched pultruded rod containing unidirectional E-glass fibers depends on the ratio of gage length L to specimen diameter d at the notch. For a tensile failure, a large L/d ratio is required. At smaller L/d ratios, long pull-out or crushing at the grips occurs. Based on the failure mode observation and tensile strength evaluation, development of a V-notched tension test with large L/d ratio is suggested as a possible replacement for the current ASTM tension test (ASTM Test Method for Tensile Properties of Pultruded Glass Fiber-Reinforced Plastic Rod left bracket D 3916 right bracket ).
引用
收藏
页码:108 / 112
相关论文
共 50 条