Determination of Cracks in Metastable Austenitic Alloys Using a Permeability Probe.

被引:0
作者
Bowe, K.H.
Hornbogen, E.
Wittkamp, I.
机构
来源
Materialpruefung | 1979年 / 21卷 / 03期
关键词
MATERIALS TESTING APPARATUS - STEEL - Crack Propagation;
D O I
暂无
中图分类号
学科分类号
摘要
It is shown how the position, size and growth rate of cracks lying below the surface can be measured with the aid of a Foerster probe. This method is suitable for materials which form a ferromagnetic phase as a result of martensitic deformation (certain austenitic steels), provided that the difference between the loading temperature and martensite temperature amounts to about 50 degree C.
引用
收藏
页码:74 / 77