Computer operated coordinated over-current protection scheme

被引:0
|
作者
Lutful Kabir, S.M.
机构
来源
Proceedings of the Universities Power Engineering Conference | 2000年
关键词
Computer aided network analysis - Computer control systems - Electric instrument transformers - Electric lines - Electric network parameters - Electric power distribution - Electric power transmission - Electric relays - Overcurrent protection;
D O I
暂无
中图分类号
学科分类号
摘要
Over-current protection scheme has very wide applications in transmission and distribution lines. In order to maintain coordination between several points of protection especially in radial feeders inverse time graded scheme is employed. The coordination is very essential in order to maintain minimum time of operation for the relay concerned as well as to provide a backup in case of failure of the particular relay. An on-line computer operated over-current protection scheme has been developed at the laboratory. A scaled down power system network has been constructed and four points within the network are chosen as points of protection. A single computer is engaged in monitoring, taking decision and controlling the protection gears of the system. The set up has been tested in the laboratory by creating short circuits through fault impedance at different points of the network. A computer program has been written in order to read input sampled voltages corresponding to the line currents, compare the currents with setting currents, calculate the time of operation of circuit breaker for a fault and send the appropriate trip signal. The user may use the setting values decided by the software. For this the user is to provide the system configuration and parameters, CT ratios and desired minimum time of operation. The software calculates the setting values and shows the results for faults at different points of protection. Alternatively, the user may define the setting values before running the program. The values are current setting for different relay points and individual time multiplier. The user is also asked to define the relay characteristic. The operation of the computer operated protection system is found to be extremely accurate. Since, in this scheme relay parameters and relay characteristics can easily be modified from the software the user may observe the effect of any change on the operation of the relays. It is very convenient learning tool both for the students and the practising engineers.
引用
收藏
相关论文
共 50 条
  • [41] Over-current testing of HTS tapes
    Lue, JWW
    Gouge, MJ
    Duckworth, RC
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 1835 - 1838
  • [42] The built-in current sensor and over-current protection of the emitter turn-off (ETO) thyristor
    Zhang, B
    Huang, AQ
    Zhou, XG
    Liu, YF
    Atcitty, S
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1264 - 1269
  • [43] Over-current protection method for PMSM VSI with small DC-link capacitor
    Xu, Yongxiang
    Huang, Yingliang
    Zheng, Boyuan
    Zhang, Wentao
    Li, Yong
    Zou, Jibin
    IET POWER ELECTRONICS, 2018, 11 (07) : 1231 - 1238
  • [44] A systematic approach for phase-fault over-current protection coordination of complex networks
    Ekanayake, J. B.
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2008, 45 (03) : 229 - 238
  • [45] A New IGBT Over-Voltage and Over-Current Protection Method Based on Active Clamp Technology
    Du, Lingzhi
    Ma, Chunguang
    Zhang, Ying
    Chen, Yuan
    Luo, Yong
    IVEC 2021: 2021 22ND INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2021,
  • [46] Test and evaluation time-inverse over-current protection algorithm using SIMULINK
    Campos, David
    Moreno, Edgar
    Torres, Domingo
    NEW ASPECTS OF SIGNAL PROCESSING AND WAVELETS, 2008, : 69 - 74
  • [47] Early warning of fault conditions of an over-current protection module in dependable communication applications
    Novak, F
    Zarnik, MS
    Macek, S
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2004, 84 (02) : 125 - 128
  • [48] Integrated High-Speed Over-Current Protection Circuit for GaN Power Transistors
    Xu, Han
    Tang, Gaofei
    Wei, Jin
    Chen, Kevin J.
    2019 31ST INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS (ISPSD), 2019, : 275 - 278
  • [49] Education of Control and Over-Current Protection Strategy for Active Three-Phase Rectifiers
    Tandukar, Sabin
    Baldwin, Thomas
    Chiu, Steve
    Hamlett, Ben
    2020 52ND NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2021,
  • [50] Study on Protection Coordination of a Flux-Lock Type SFCL With Over-Current Relay
    Kim, J. S.
    Lim, S. H.
    Kim, J. C.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1159 - 1163