Computer operated coordinated over-current protection scheme

被引:0
|
作者
Lutful Kabir, S.M.
机构
来源
Proceedings of the Universities Power Engineering Conference | 2000年
关键词
Computer aided network analysis - Computer control systems - Electric instrument transformers - Electric lines - Electric network parameters - Electric power distribution - Electric power transmission - Electric relays - Overcurrent protection;
D O I
暂无
中图分类号
学科分类号
摘要
Over-current protection scheme has very wide applications in transmission and distribution lines. In order to maintain coordination between several points of protection especially in radial feeders inverse time graded scheme is employed. The coordination is very essential in order to maintain minimum time of operation for the relay concerned as well as to provide a backup in case of failure of the particular relay. An on-line computer operated over-current protection scheme has been developed at the laboratory. A scaled down power system network has been constructed and four points within the network are chosen as points of protection. A single computer is engaged in monitoring, taking decision and controlling the protection gears of the system. The set up has been tested in the laboratory by creating short circuits through fault impedance at different points of the network. A computer program has been written in order to read input sampled voltages corresponding to the line currents, compare the currents with setting currents, calculate the time of operation of circuit breaker for a fault and send the appropriate trip signal. The user may use the setting values decided by the software. For this the user is to provide the system configuration and parameters, CT ratios and desired minimum time of operation. The software calculates the setting values and shows the results for faults at different points of protection. Alternatively, the user may define the setting values before running the program. The values are current setting for different relay points and individual time multiplier. The user is also asked to define the relay characteristic. The operation of the computer operated protection system is found to be extremely accurate. Since, in this scheme relay parameters and relay characteristics can easily be modified from the software the user may observe the effect of any change on the operation of the relays. It is very convenient learning tool both for the students and the practising engineers.
引用
收藏
相关论文
共 50 条
  • [31] Open-Circuit Fault in EHV/UHV Transmission System and New Zero Sequence Over-current Protection Scheme
    Liu, Yadong
    Sun, Jiwei
    Gong, Guangshun
    Zhang, Xiaoli
    Zhang, Lie
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3093 - 3098
  • [32] A Modified Over-Current Relaying Scheme for Highly PV Connected Distribution System
    Sunil Kumar Maurya
    Surayanarayana Gangolu
    Saumendra Sarangi
    Arabian Journal for Science and Engineering, 2023, 48 : 5979 - 5990
  • [33] A Modified Over-Current Relaying Scheme for Highly PV Connected Distribution System
    Maurya, Sunil Kumar
    Gangolu, Surayanarayana
    Sarangi, Saumendra
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (05) : 5979 - 5990
  • [34] Research on the Power Line Three-stage Over-current Protection Simulation
    Yang, Yujie
    Zhu, Liancheng
    Li, Fuyun
    Wu, Zhitao
    Cai, Changyou
    Proceedings of the 2016 6th International Conference on Advanced Design and Manufacturing Engineering (ICADME 2016), 2016, 96 : 13 - 18
  • [35] Over-current Protection for Series-connected IGBTs based on Desaturation Detection
    Yue, Lu
    Saeed, Muhammad Abubakr
    Lee, Inhwan
    Yao, Xiu
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 3428 - 3435
  • [36] Analysis and optimization of LLC resonant converter with a novel over-current protection circuit
    Xie, Xiaogao
    Zhang, Junming
    Zhao, Chen
    Zhao, Zhuo
    Qian, Zhaoming
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 435 - 443
  • [37] Optimal setting method of inverse time over-current protection for distribution network
    Yang K.
    Huang C.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (03): : 163 - 168
  • [38] Development of fast electronic over-current protection circuit using current-adjustable sensing method
    Lin, Hsiung-Cheng
    He, Bo-Rong
    Zo, Heng-Chuan
    Hsiao, Kai-Chun
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (04)
  • [39] A New Over-Current Protection Technique for Peak- Current Type DC-DC Converter
    Fang, Yu
    Xie, Yong
    Wei, Tengfei
    Xing, Yan
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1874 - +
  • [40] Design and Implementation of an Over-Current Relay for the Power Electronic-based Converters Protection
    Ebadifard, Majid
    Zaker, Hamidreza
    Kargar, Hossein Kazemi
    2019 INTERNATIONAL CONFERENCE ON PROTECTION AND AUTOMATION OF POWER SYSTEM (IPAPS), 2019, : 49 - 54