Effects of timing on ventriculoarterial coupling and mechanical efficiency during intraaortic balloon pumping

被引:0
|
作者
Sakamoto, Tohru
Suzuki, Akio
Kazama, Shigeru
Komatsu, Shigeo
Sasaki, Shin
Shoji, Yasushi
机构
来源
ASAIO Journal | 1995年 / 41卷 / 03期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Ventricular energetics during mechanical ventilation and intraaortic balloon pumping - computer simulation
    De Lazzari, C
    Darowski, M
    Ferrari, G
    Clemente, F
    Guaragno, M
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (03) : 103 - 111
  • [2] CARDIAC ENERGY CONSIDERATIONS DURING INTRAAORTIC BALLOON PUMPING
    BARNEA, O
    MOORE, TW
    DUBIN, SE
    JARON, D
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (02) : 170 - 181
  • [3] Working pressure for full balloon inflation during intraaortic balloon pumping
    Sakamoto, T
    Akamastu, H
    Arai, H
    Shoji, Y
    Komatsu, S
    Sasaki, S
    Kazama, S
    Fujiyoshi, K
    Hashiguchi, Y
    Suzuki, A
    Suzuki, A
    ARTIFICIAL ORGANS, 1997, 21 (02) : 171 - 173
  • [4] INTRAAORTIC BALLOON PUMPING IN EXPERIMENTAL ANIMAL - EFFECTS AND PROBLEMS
    FEOLA, M
    ADACHI, M
    AKERS, WW
    ROSS, JN
    WIETING, DW
    KENNEDY, JH
    AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (02): : 129 - &
  • [5] EFFECTS OF INFRARENAL INTRAAORTIC BALLOON PUMPING ON RENAL HEMODYNAMICS
    AGISHI, T
    TERAOKA, S
    SANAKA, T
    OTA, K
    KIDNEY INTERNATIONAL, 1983, 23 (01) : 241 - 241
  • [6] EFFECTS OF INTRAAORTIC BALLOON PUMPING DURING RIGHT VENTRICULAR INFLOW OBSTRUCTION IN THE NEWBORN LAMB
    BERNSTEIN, D
    SHADDY, R
    TYNDALL, M
    RUDOLPH, AM
    PEDIATRIC RESEARCH, 1987, 21 (04) : A197 - A197
  • [7] Assessment of coronary bypass flow during intraaortic balloon pumping
    Walpoth, BH
    Springe, D
    Berdat, P
    Kipfer, B
    Neidhart, P
    Eberli, F
    Hess, OM
    Carrel, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 197A - 197A
  • [8] Effects of intraaortic balloon pumping on coronary and carotid flow during percutaneous cardiopulmonary support
    Geppert, A
    Frey, B
    Gabriel, H
    Kratochwill, C
    Siostrzonek, P
    ANNALS OF THORACIC SURGERY, 1996, 61 (05): : 1539 - 1541
  • [9] Effects of dobutamine on left ventriculoarterial coupling and mechanical efficiency in acutely ischemic pigs
    Kolh, P
    Lambermont, B
    Ghuysen, A
    Tchana-Sato, V
    Dogne, JM
    Hanson, J
    Gerard, P
    D'Orio, V
    Pierard, L
    Limet, R
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2005, 45 (02) : 144 - 152
  • [10] PHYSIOLOGIC EFFECTS OF INTRAAORTIC BALLOON PUMPING IN CARDIOGENIC-SHOCK
    SCHEIDT, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02): : 290 - &