APPLICATION OF A VORTEX-SHEDDING FLOWMETER TO THE WIDE-RANGE MEASUREMENT OF HIGH-TEMPERATURE GAS FLOW.

被引:0
|
作者
BAKER, STEVEN P.
HERNDON, P.G.
ENNIS, ROBERT M.JR.
机构
来源
| 1982年 / V 21卷 / N 1期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A SINGLE FLOWMETER WAS REQUIRED FOR HELIUM GAS MEASUREMENT IN A GAS-COOLED FAST BREEDER REACTOR CORE FLOW SIMULATOR. VOLUMETRIC FLOW ACCURACY OF +- 1. 0 PERCENT OF READING WAS REQUIRED OVER THE PIPE REYNOLDS NUMBER RANGE 6 * 10**3 TO 1 * 10**6 AT PRESSURES FROM 0. 2 TO 9 MPA AND AT 350 D. TEMPERATURE. A VORTEX-SHEDDING FLOWMETER WITH A REMOTELY LOCATED THERMAL SENSOR WAS EMPLOYED. THE RELATIONSHIPS AMONG THERMAL SENSOR SIGNAL, SENSOR CONNECTING TUBING GEOMETRY, AND FLOWING CONDITIONS WERE DETERMINED EMPIRICALLY FOR BOTH AIR AND HELIUM GAS FLOW. THE GEOMETRY FOR REMOTELY LOCATING THE SENSOR WAS OPTIMIZED TO PROVIDE WIDE FLOW RANGEABILITY FOR HIGH-TEMPERATURE HELIUM GAS FLOW. VOLUMETRIC FLOW ACCURACY WAS MEASURED OVER A RANGE OF 348:1 IN FLOW AND 46:1 IN DENSITY. VOLUMETRIC FLOW ACCURACY OF +- 1. 75 PERCENT OF READING WAS DEMONSTRATED OVER A RANGE OF 288:1 IN FLOW.
引用
收藏
页码:23 / 30
相关论文
共 38 条
  • [1] APPLICATION OF A VORTEX-SHEDDING FLOWMETER TO THE WIDE-RANGE MEASUREMENT OF HIGH-TEMPERATURE GAS-FLOW
    BAKER, SP
    HERNDON, PG
    ENNIS, RM
    ISA TRANSACTIONS, 1982, 21 (01) : 23 - 30
  • [2] UNIVERSAL DEVICE FOR MATERIAL TESTING IN WIDE-RANGE OF GAS-PRESSURES AT HIGH-TEMPERATURE
    BONDARENKO, MD
    ZAVODSKAYA LABORATORIYA, 1975, 41 (07): : 817 - 819
  • [3] Development of high-temperature wide-range humidity sensor by wetted material temperature measurement (application of porous ceramic into sensing element)
    Toyo College of Food Technology, 4-23-2, Minamihanayashiki, Kawanishi-shi, Hyogo, 666-0026, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2012, 792
  • [4] Advanced Photonic Vortex Flowmeter with interferometer sensor for measurement of wide dynamic range of medium velocity at high temperature and high pressure
    Krisch, Henrik
    Niermann, Benedikt
    Gedikli, Ali
    Tenderenda, Tadeusz
    Nasilowski, Tomasz
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
  • [5] High-Temperature and Wide-Range Anemometer Based on Plasma Glow Discharge
    Liu, Xianlong
    Chen, Guochun
    Zhou, Paidi
    Xu, Yi
    Li, Xin
    Cui, Zaifu
    Cui, Jinting
    Hai, Zhenyin
    Chen, Qinnan
    Sun, Daoheng
    IEEE SENSORS JOURNAL, 2022, 22 (04) : 3067 - 3073
  • [6] THE WIDE-RANGE EJECTOR FLOWMETER - CALIBRATED GAS EVACUATION COMPRISING BOTH HIGH AND LOW GAS-FLOWS
    WAABEN, J
    BRINKLOV, MM
    JORGENSEN, S
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1984, 31 (06) : 695 - 698
  • [7] Rapid and wide-range pressure measurement at high-temperature using an intensity-compensation interrogation method
    Li, Zhiyuan
    Wang, Shuang
    Shao, Zhiqiang
    Jiang, Junfeng
    Yang, Haokun
    Sun, Zhiqiang
    Yan, Meiyu
    Liu, Tiegen
    OPTICS AND LASERS IN ENGINEERING, 2022, 157
  • [8] DISTRIBUTION OF DISPERSE-PHASE VAPORS IN A HIGH-TEMPERATURE GAS FLOW.
    Lamden, D.I.
    Stonik, O.G.
    Journal of Engineering Physics (English Translation of Inzhenerno-Fizicheskii Zhurnal), 1985, 48 (02): : 131 - 133
  • [9] BREAKDOWN OF AN ORGANICALLY BASED COMPOSITE MATERIAL IN A HIGH-TEMPERATURE GAS FLOW.
    Nikitin, P.V.
    Ovsyannikov, V.M.
    Kholodkov, N.V.
    Journal of Engineering Physics (English Translation of Inzhenerno-Fizicheskii Zhurnal), 1986, 50 (03): : 261 - 266
  • [10] Development of high-temperature wide-range humidity sensor by wetted material temperature measurement (improvement of measurement accuracy by considering the effect of supplied water)
    Kitahara, Takashi
    Iyota, Hiroyuki
    Inoue, Tamotsu
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2012, 78 (787): : 686 - 696