CHARACTERIZATION OF METAL POWDERS USING A COULTER COUNTER.

被引:0
|
作者
Brauns, E.
Helsen, J.A.
Roos, J.R.
机构
来源
| 1978年 / 2卷 / 01期
关键词
POWDER METALLURGY;
D O I
暂无
中图分类号
学科分类号
摘要
Measurements of the particle size distribution of meta powders using a Coulter Counter do not always give reliable results. The conventional instrument exhibits for this purpose some basic shortcomings in the design of the orifice tube. This paper shows that some particles were counted several times, resulting in erratic countings. Moreover, when sizing conducting particles, the usual equation expressing the relationship between particle diameter and pulse height has to be modified. A modified orifice tube is proposed. Other improvements such as screening of the sample beaker and homogenization of the suspension of metal particles are also discussed.
引用
收藏
页码:56 / 61
相关论文
共 50 条
  • [21] ELECTRONIC PIECE PARTS COUNTER.
    Rush, Peter
    Electrical Engineer (Melbourne), 1973, 50 (06): : 20 - 22
  • [22] The reason for the breakdown of a Discharge counter.
    Schade, R
    NATURWISSENSCHAFTEN, 1938, 26 : 546 - 547
  • [23] LEUKOCYTE CHEMOTAXIS - MIXED POPULATION CHARACTERIZATION UTILIZING COULTER-COUNTER AND COULTER CHANNELYZER
    MARTLAGE, KA
    BROWN, CE
    FEDERATION PROCEEDINGS, 1977, 36 (03) : 796 - 796
  • [24] Differentiating neutrophils using the optical coulter counter
    Schonbrun, Ethan
    Di Caprio, Giuseppe
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (11)
  • [25] PLATELET COUNTING USING COULTER ELECTRONIC COUNTER
    EGGLETON, MJ
    SHARP, AA
    JOURNAL OF CLINICAL PATHOLOGY, 1963, 16 (02) : 164 - &
  • [26] A new form of the Geiger counter.
    Steenbeck, Max
    ZEITSCHRIFT FUR PHYSIK, 1931, 71 (7-8): : 422 - 430
  • [27] LARGE LIQUID SCINTILLATION COUNTER.
    Bozhko, N.I.
    Vovenko, A.S.
    Glebov, V.Yu.
    Goryachev, V.N.
    Kochetkov, V.I.
    Kvartsov, V.I.
    Poletaev, V.I.
    Salomatin, Yu.I.
    Rychenkov, V.N.
    Chernichenko, S.K.
    Fakhrutdinov, R.M.
    Shchukin, G.L.
    Instruments and experimental techniques New York, 1985, 28 (2 pt 1): : 325 - 329
  • [28] EXTENDED RANGE WELL COUNTER.
    Nickles, R.J.
    Votaw, J.R.
    1600, (NS-32):
  • [29] Differentiating neutrophils using the optical Coulter counter
    Schonbrun, E.
    Di Caprio, G.
    QUANTITATIVE PHASE IMAGING, 2015, 9336
  • [30] Note on the correction to be applied to the results obtained by using a Geiger counter.
    Todd, H
    PHILOSOPHICAL MAGAZINE, 1937, 24 (162): : 572 - 582