Comparison of microemulsion electrokinetic chromatography and solvent-modified micellar electrokinetic chromatography

被引:0
|
作者
Hansen, Steen Honoré [1 ,3 ]
Gabel-Jensen, Charlotte [1 ]
Pedersen-Bjergaard, Stig [2 ]
机构
[1] Department of Analytical and Pharmaceutical Chemistry, Royal Danish School of Pharmacy, Copenhagen, Denmark
[2] School of Pharmacy, University of Oslo, Oslo, Norway
[3] Department of Analytical and Pharmaceutical Chemistry, Royal Danish School of Pharmacy, Universitetsparken 2, DK-2100 Copenhagen, Denmark
关键词
Methanol - Microemulsions - Organic solvents - Separation - Surface active agents;
D O I
10.1002/1615-9314(20010801)24:83.0.CO;2-U
中图分类号
学科分类号
摘要
Microemulsion electrokinetic chromatography (MEEKC) was investigated with the goal of elucidating the influence exerted by the amount of lipophilic organic phase and the amount of co-surfactant on the migration of a number of neutral test solutes. Furthermore, MEEKC was compared to solvent-modified micellar electrokinetic chromatography (MEKC). The organic solvents methanol, ethanol, 1-propanol, 1-butanol, acetonitrile, tetrahydrofuran, and 2-ethoxyethanol serving as co-surfactants in MEEKC were used in similar concentrations in MEKC systems in order to compare the selectivity and separation efficiency of the two kinds of system. The solvent-modified MEKC technique proved to be very similar to MEEKC in performance with respect to both separation selectivity and efficiency of separation.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of microemulsion electrokinetic chromatography and solvent-modified micellar electrokinetic chromatography
    Hansen, SH
    Gabel-Jensen, C
    Pedersen-Bjergaard, S
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (08): : 643 - 650
  • [2] Microemulsion electrokinetic chromatography - or solvent-modified micellar electrokinetic chromatography?
    Hansen, SH
    Gabel-Jensen, C
    El-Sherbiny, DTM
    Pedersen-Bjergaard, S
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (11) : 614 - 619
  • [3] MICROEMULSION ELECTROKINETIC CHROMATOGRAPHY - COMPARISON WITH MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    TERABE, S
    MATSUBARA, N
    ISHIHAMA, Y
    OKADA, Y
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 23 - 29
  • [4] Optimization of the separation of flavonoids using solvent-modified micellar electrokinetic chromatography
    Tonin, FG
    Jager, AV
    Micke, GA
    Farah, JRS
    Tavares, MFM
    ELECTROPHORESIS, 2005, 26 (17) : 3387 - 3396
  • [5] Comparison of microemulsion electrokinetic chromatography and micellar electrokinetic chromatography as methods for the analysis of ten benzophenones
    Huang, HY
    Chiu, CW
    Chen, YC
    Yeh, JM
    ELECTROPHORESIS, 2005, 26 (4-5) : 895 - 902
  • [6] Comparison and prediction of the retention in micellar electrokinetic chromatography and microemulsion electrokinetic chromatography for disubstituted benzenes
    Angkanasiriporn, Siriporn
    Singsung, Wuttipong
    Petsom, Amorn
    Nhujak, Thumnoon
    ELECTROPHORESIS, 2010, 31 (04) : 695 - 701
  • [7] Comparison of microemulsion electrokinetic chromatography and micellar electrokinetic chromatography methods for the analysis of phenolic compounds
    Huang, HY
    Lien, WC
    Chiu, CW
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (9-10) : 973 - 981
  • [8] Comparison of microemulsion electrokinetic chromatography and solvent modified micellar electrokinetic chromatograph on rapid separation of heroin, amphetamine and their basic impurities
    Wen, Tao
    Zhao, Xia
    Luo, Guoan
    Wang, Jian
    Wang, Yiming
    Yao, Bo
    Zhao, Jiyuan
    Zhu, Jun
    Yu, Zhongshan
    TALANTA, 2007, 71 (02) : 854 - 860
  • [9] Separation of cardiac glycosides by micellar electrokinetic chromatography and microemulsion electrokinetic chromatography
    Debusschere, L
    Demesmay, C
    Rocca, JL
    Lachatre, G
    Lofti, H
    JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 227 - 233
  • [10] Microemulsion and micellar electrokinetic chromatography of steroids
    Vomastova, L
    Miksik, I
    Deyl, Z
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (01): : 107 - 113