Continuous ohmic heating unit under whey protein fouling

被引:30
作者
Ayadi, M.A. [1 ]
Leuliet, J.C. [1 ]
Chopard, F. [2 ]
Berthou, M. [3 ]
Lebouché, M. [4 ]
机构
[1] INRA, LGPTA, 59650 Villeneuve D'Ascq Cedex
[2] ALFA LAVAL VICARB, 38120 Fontanil Cornillon, rue du Rif Tronchard
[3] EDF-R and D, 77818 Moret Sur Loing Cedex, Les Renardières
[4] LEMTA, 54504 Vandoeuvre-lès-Nancy
关键词
Dairy fluid; Fouling monitoring; Ohmic heating;
D O I
10.1016/j.ifset.2004.08.001
中图分类号
学科分类号
摘要
An evaluation of a continuous ohmic heating apparatus performance was carried out, using a whey protein solution. It was thereby shown that, as with conventional heat exchangers, ohmic processing of dairy product generates fouling on electrode surfaces. The presence of this motionless deposit causes an increase in electricity consumption and leads to an increase in the temperature of the electrode surfaces. During the observation of 4- and 6-h processes, three stages were noted: (i) at first, the deposit thickness was not significant for a short period and ohmic process was observed to operate satisfactorily (balance power, electrode temperature), (ii) then the deposit thickness was observed to gradually increase with processing time, provoking a corresponding simultaneous increase in both electricity comsuption and electrode temperature, (iii) finally, the electrode temperature reached boiling point, as did the deposit, leading to deposit adhesion and removal changes. © 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:465 / 473
页数:8
相关论文
共 28 条
[1]  
Amatore C., Berthou M., Hebert S., Fundamental principles of electrochemical ohmic heating of solutions, Electroanalytical Chemistry, 457, pp. 191-203, (1998)
[2]  
Anderson A.K., Finkelsten R., A study of the electro-pure process of treating milk, Journal of Dairy Science, 2, pp. 374-406, (1919)
[3]  
Ayadi M.A., Chopard F., Berthou M., Fillaudeau L., Leuliet J.-C., Comparaison entre le comportement hydrodynamique et la répartition de dépôt encrassant dans des cellules ohmiques, Récents Progrès En Génie des Procédés, 90, pp. 14-21, (2003)
[4]  
Belmar-Beiny M.T., Gotham S.M., Paterson W.R., Fryer P.J., The effect of Reynolds number and fluid temperature in whey protein fouling, Journal of Food Engineering, 19, pp. 119-139, (1993)
[5]  
Benabderrahmane Y., Pain J.P., Thermal behaviour of a solid/liquid mixture in an ohmic heating sterilizer - Slip phase model, Chemical Engineering Science, 55, pp. 1371-1384, (2000)
[6]  
Berthou M., Aussudre C., (1999)
[7]  
Burton H., Reviews of the progress of dairy science, Journal of Dairy Research, 34, pp. 317-330, (1968)
[8]  
Butterworth D., Design of shell-and-tube heat exchanger when the fouling depends on local temperature and velocity, Applied Thermal Engineering, pp. 789-801, (2002)
[9]  
Changani S.D., Belmar-Beiny M.T., Fryer P.J., Engineering and chemical factors associated with fouling and cleaning in milk processing, Experimental Thermal and Fluid Science, 14, pp. 392-406, (1997)
[10]  
De Alwis A.A.P., Halden K., Fryer P.J., Shape and conductivity effects in the ohmic heating of foods, Chemical Engineering Research & Design, 67, pp. 159-168, (1989)