Handy and Accurate Measuring Device for Controlling Maximum and Minimum Loads during Fatigue Tests.

被引:0
|
作者
Frank, Th.
Schleip, R.
Meven, W.
机构
来源
Materialpruefung/Materials Testing | 1975年 / 17卷 / 11期
关键词
MATERIALS TESTING - Fatigue;
D O I
暂无
中图分类号
学科分类号
摘要
Differences were observed in results reported by different laboratories testing presumably the same materials and structural components in pulsator-type fatigue testing machines. This led to suspecting the accuracy of the machines, which was confirmed by measurements. The portable dynamometer described was developed for checking whether the load applied coincides with the load recorded by the machine.
引用
收藏
页码:401 / 402
相关论文
共 15 条
  • [1] DEVICE FOR ACCURATE MEASUREMENT OF VARIABLE LOADS IN FATIGUE TESTS
    ALEKSAND.BI
    YANKOV, GI
    INDUSTRIAL LABORATORY, 1965, 31 (12): : 1914 - &
  • [2] Determination of the Fatigue Curve through a Minimum Number of Short-Duration Tests.
    Leroy, A.
    Viseur, B.
    1600, (20):
  • [3] Internal Friction and Fatigue During Symmetrical Alternating Bending Tests.
    Lalubin, J.L.
    Joubert, F.
    Mecanique-Materiaux-Electricite, 1976, (320-321): : 37 - 40
  • [4] Thermal Stresses Occurring During High-Frequency Fatigue Tests.
    Troyan, I.A.
    Shevchuk, A.D.
    Tsimbalistyi, Ya.I.
    Problemy Prochnosti, 1973, 5 (02): : 65 - 69
  • [5] ON METHODS OF MEASURING TEMPERATURE DURING FATIGUE TESTS
    ZAKHAROVA, TP
    INDUSTRIAL LABORATORY, 1959, 25 (12): : 1583 - 1587
  • [6] METHOD OF EXPERIMENTALLY CHECKING THERMODYNAMIC IDEAS ON THE FAILURE OF A SOLID BODY DURING FATIGUE TESTS.
    Romashov, R.V.
    Fedorov, V.V.
    Industrial Laboratory (USSR) (English translation of Zavodskaya Laboratoriya), 1975, 41 (02): : 281 - 284
  • [7] RADIATION METHOD OF MEASURING TEMPERATURE OF A METAL DURING FATIGUE TESTS
    FRANYUK, VA
    MALKO, II
    RANTSEVICH, VB
    INDUSTRIAL LABORATORY, 1971, 37 (12): : 1900 - +
  • [8] Optimal Evaluations of Thermal Stresses and the Exchange Conditions in Turbine Blades During Thermal Fatigue Tests.
    Simbirskii, D.F.
    Bogdanov, V.G.
    Problemy Prochnosti, 1974, 6 (09): : 110 - 116
  • [9] A robotic device for measuring and controlling pelvic motion during locomotor rehabilitation
    Ichinose, WE
    Reinkensmeyer, DJ
    Aoyagi, D
    Lin, JT
    Ngai, K
    Edgerton, VR
    Harkema, SJ
    Bobrow, JE
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1690 - 1693
  • [10] DEVICE FOR MEASURING SMALL DEFORMATIONS DURING COMPRESSION TESTS ON ROCKS SAMPLES
    KURBATOV, VM
    INDUSTRIAL LABORATORY, 1958, 24 (10): : 1407 - 1408