Calculation of stator winding leakage reactance of 3 and 12-phase machines with AC and DC output

被引:0
|
作者
Wu, Xusheng [1 ]
Ma, Weiming [1 ]
Gu, Weifeng [1 ]
Sun, Junzhong [1 ]
Yang, Qing [1 ]
机构
[1] Inst. of Power Electron. Tech., Naval Univ. of Eng., Wuhan 430033, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
3/12-phase synchronous machines with AC and DC output are being widely used in self-contained electrical power systems for their obvious virtues. On their stator, two separate windings are distributed, one three-phase winding delivers AC power and the other twelve-phase winding, termed DC windings, are connected to the bridge rectifier to supply DC power. Unlike ordinary three-phase machines, there are four layers winding in each stator slot of the 3/12-phase machine and the total air gap magnetometive force produced by the 12-phase winding is more complex than 3-phase machines. By analyzing the leakage magnetic flux and the magnetometive force, relevant formulas are derived to calculate the leakage reactances of the machines. All the stator leakage reactances of a realistic 3 and 12-phase machine were calculated through the methods presented and the simulation of a sudden short-circuit test of the machine was carried out with the parameters calculated. The simulation and test results agree quite well, and show that the formulas presented are correct.
引用
收藏
页码:9 / 13
相关论文
共 37 条
  • [21] Voltage-behind-reactance model of six-phase synchronous machines considering stator mutual leakage inductance and main flux saturation
    Amiri, Navid
    Ebrahimi, Seyyedmilad
    Chapariha, Mehrdad
    Jatskevich, Juri
    Dommel, Hermann W.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 138 : 155 - 164
  • [22] Separate Double-winding 12-phase Brushless DC Motor Drive Fed from Individual H-Bridge Inverters
    Cho, Byung-Geuk
    Yoon, Young-Doo
    Sul, Seung-Ki
    Kong, Young Kyung
    Bin, Jae Goo
    Park, Sun Jung
    Lee, Man Li
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 3889 - 3895
  • [23] DETERMINATION OF THE END-TURN LEAKAGE REACTANCE OF A 3-PHASE TOROIDAL WINDING BY A METHOD OF HARMONIC-ANALYSIS
    LOPUKHINA, YM
    GASI, EH
    ELECTRICAL TECHNOLOGY, 1993, (01): : 23 - 38
  • [25] Analysis of Stator Winding Inter-Turn Short Circuit on a 12-Phase Rectifier Generator System Based on Finite Element Field-Circuit Coupling
    Zhang Y.
    Zheng X.
    Wu X.
    Lin N.
    Wei K.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 (09): : 1842 - 1849
  • [26] Reduction of On-Load DC Winding-Induced Voltage in Partitioned Stator Wound Field Switched Flux Machines by Dual Three-Phase Armature Winding
    Wu, Zhongze
    Zhu, Z. Q.
    Wang, Chao
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (06) : 5409 - 5420
  • [27] DETERMINATION OF THE HARMONIC LEAKAGE AND TOOTH TIP LEAKAGE INDUCTANCES OF 3 PHASE AC MACHINES USING THE FIELD-THEORY
    STIEBLER, M
    RITTER, C
    ARCHIV FUR ELEKTROTECHNIK, 1982, 65 (06): : 355 - 362
  • [28] Effect of AC-side load on the sudden DC-side short-circuit current of a 3-&12-phase double-winding AC-DC generator
    Sun, JZ
    Jiang, HL
    Song, ZH
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 722 - 725
  • [29] A Research on the DC-Link Current and Capacitance of the Static Excitation Regulator on a 12/3-Phase Dual Stator-Winding Induction Generator
    Zhang, Botao
    Wang, Dong
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS II, 2012, 214 : 154 - +
  • [30] Analytical Calculation of the Difference in Parallel Output Current Between the 12-pulse Rectifier Bridges Based on Transformer Leakage Inductance and DC inter-phase Reactor
    Jiang, Linfei
    Xiao, Fei
    Hu, Liangdeng
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 623 - 629