Calculation of stator winding leakage reactance of 3 and 12-phase machines with AC and DC output

被引:0
|
作者
Wu, Xusheng [1 ]
Ma, Weiming [1 ]
Gu, Weifeng [1 ]
Sun, Junzhong [1 ]
Yang, Qing [1 ]
机构
[1] Inst. of Power Electron. Tech., Naval Univ. of Eng., Wuhan 430033, China
关键词
D O I
暂无
中图分类号
学科分类号
摘要
3/12-phase synchronous machines with AC and DC output are being widely used in self-contained electrical power systems for their obvious virtues. On their stator, two separate windings are distributed, one three-phase winding delivers AC power and the other twelve-phase winding, termed DC windings, are connected to the bridge rectifier to supply DC power. Unlike ordinary three-phase machines, there are four layers winding in each stator slot of the 3/12-phase machine and the total air gap magnetometive force produced by the 12-phase winding is more complex than 3-phase machines. By analyzing the leakage magnetic flux and the magnetometive force, relevant formulas are derived to calculate the leakage reactances of the machines. All the stator leakage reactances of a realistic 3 and 12-phase machine were calculated through the methods presented and the simulation of a sudden short-circuit test of the machine was carried out with the parameters calculated. The simulation and test results agree quite well, and show that the formulas presented are correct.
引用
收藏
页码:9 / 13
相关论文
共 37 条
  • [1] Research on Stator Winding Leakage Reactance Calculation of Double-winding AC-DC Generator
    Wu Xusheng
    Gao Wei
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 6861 - 6867
  • [2] Numerical Calculation of Stator End Leakage Reactance of Permanent Magnet Machines with Concentric Winding
    Zheng, Xiaoqin
    Zhang, Wen
    Wu, Xinzhen
    Ni, Ronggang
    JOURNAL OF MAGNETICS, 2019, 24 (01) : 184 - 189
  • [3] Research on calculation of leakage reactance of dual stator-winding induction generator
    Aero-Power Sci-Tech Center, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    不详
    Hangkong Xuebao, 2006, 1 (109-114):
  • [4] Study on mathematical model of 3/12-phase synchronous generators with AC and bridge rectified DC output
    Sun, Jun-Zhong
    Ma, Wei-Ming
    Wu, Xu-Sheng
    Yang, Qing
    Liu, De-Zhi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2003, 23 (01): : 93 - 96
  • [5] Effective Simulation of Stability of 3/12-phase Synchronous Generators with Simultaneous AC and DC Stator Connections Using MATLAB
    Wang Shanming
    Zhang Anming
    Wang Xiangheng
    Su Pengsheng
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4160 - +
  • [6] Calculation of stator harmonic leakage inductances for 12/3-phase dual-winding induction generator
    Wu, Xin-Zhen
    Wang, Xiang-Heng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (24): : 80 - 84
  • [7] Calculation of stator harmonic leakage inductances for 12/3-phase dual-winding induction generator
    Wu, Xin-Zhen
    Wang, Xiang-Heng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (21): : 71 - 75
  • [8] CALCULATION OF LEAKAGE REACTANCE OF A 3 PHASE TRANSFORMER
    LEBEDEV, VK
    ANDREEV, VV
    AUTOMATIC WELDING USSR, 1966, 19 (06): : 40 - &
  • [9] Calculation of stator winding inter-turn short circuit in 12-phase synchronous generators with rectifier load system
    Sun, Yuguang
    Huang, Ziguo
    Chen, Li
    Wang, Xiangheng
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2014, 29 (03): : 57 - 64
  • [10] Measurement of steady-state reactance of multi-phase synchronous machines with AC and DC output
    Wu, X.S.
    Ma, W.M.
    Zhang, G.F.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2001, 16 (03):