MULTIDIMENSIONAL SLIT-SCAN FLOW SYSTEM.

被引:0
|
作者
Cambier, James L.
Kay, David B.
Wheeless Jr., Leon L.
机构
来源
| 1979年
关键词
BIOLOGICAL MATERIALS - Measurements - FLUORESCENCE - Measurements - LASER BEAMS - Applications - PATTERN RECOGNITION SYSTEMS - Computer Applications;
D O I
暂无
中图分类号
学科分类号
摘要
A new slit-scan type flow system is described which provides three (X, Y, and Z) orthogonal one-dimensional projections of cell fluorescence. A photomultiplier tube and two semiconductor array detectors are used to obtain the three slit-scan contours from cells traversing a single fluorescence excitation beam. A high speed, dedicated preprocessor analyzes the three contours in parallel, extracting certain features useful for rejecting cells from which an accurate measurement of nuclear fluorescence cannot be obtined. Contour data is buffered and transferred to a PDP-11/40 compuer where nuclear fluorescence is measured and cells are classified. It is anticipated that this new instrument will provide a significant reduction in false alarm rate when applied to prescreening of gynecologic cytology specimens.
引用
收藏
页码:321 / 324
相关论文
共 50 条
  • [41] SLIT-SCAN FLOW-CYTOMETRY AS A TOOL FOR QUANTATIVE EVALUATION OF STRUCTURAL-CHANGES IN CHROMOSOMES
    LUCAS, JN
    GRAY, JW
    JOURNAL OF CELL BIOLOGY, 1981, 91 (02): : A3 - A3
  • [42] EXPECTATION VALUES FOR PARAMETER SETS MEASURED IN SLIT-SCAN FLOW-CYTOMETRY - CANCER PRESCREENING
    MULLANEY, PF
    ACHATZ, M
    SEGER, G
    SINSEL, F
    HEINZE, W
    WEISS, B
    MANN, R
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1981, : 448 - 452
  • [43] DNA SLIT-SCAN FLOW-CYTOMETRY OF BLADDER IRRIGATION SPECIMENS AND THE IMPORTANCE OF RECOGNIZING UROTHELIAL CELLS
    WHEELESS, LL
    REEDER, JE
    OCONNELL, MJ
    ROBINSON, RD
    COSGRIFF, JM
    FRADET, Y
    FRANK, IN
    COCKETT, ATK
    CYTOMETRY, 1991, 12 (02): : 140 - 146
  • [44] COMPUTERIZED SLIT-SCAN CYTO-FLUOROMETER FOR AUTOMATED CELL RECOGNITION
    WHEELESS, LL
    PATTEN, SF
    FEDERATION PROCEEDINGS, 1970, 29 (02) : A945 - +
  • [45] Fast slit-scan method for MTF and MRTD characterization in the HITL environment
    Smith, JL
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING VII, 1996, 2743 : 206 - 215
  • [46] A PULSE-GENERATOR SIMULATING SLIT-SCAN CHROMOSOME ANALYSIS SIGNALS
    WEIER, HU
    EISERT, WG
    CYTOMETRY, 1986, 7 (01): : 98 - 100
  • [47] 2-PARAMETER DATA ACQUISITION-SYSTEM FOR RAPID SLIT-SCAN ANALYSIS OF MAMMALIAN CHROMOSOMES
    WEIER, HU
    EISERT, WG
    CYTOMETRY, 1987, 8 (01): : 83 - 90
  • [48] SLIT-SCAN FLOW-CYTOMETRY - ANALYSIS OF CHINESE-HAMSTER M3-1 CHROMOSOMES
    GRAY, JW
    LUCAS, J
    PINKEL, D
    PETERS, D
    ASHWORTH, L
    VANDILLA, MA
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA SECTION A-PATHOLOGY, 1981, : 249 - 255
  • [49] EXPECTATION VALUES FOR LOW-RESOLUTION SLIT-SCAN FLOW PRESCREENING - INFLUENCE OF NUCLEAR SHAPE AND DNA DENSITY
    MULLANEY, PF
    MANN, R
    SEGER, GH
    ACHATZ, M
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1982, 4 (02): : 115 - 122
  • [50] EFFECTIVENESS OF PULSE-SHAPE CRITERIA FOR THE SELECTION OF DICENTRIC CHROMOSOMES BY SLIT-SCAN FLOW-CYTOMETRY AND SORTING
    RENS, W
    VANOVEN, CH
    STAP, J
    ATEN, JA
    ANALYTICAL CELLULAR PATHOLOGY, 1993, 5 (03): : 147 - 159