MULTIDIMENSIONAL SLIT-SCAN FLOW SYSTEM.

被引:0
|
作者
Cambier, James L.
Kay, David B.
Wheeless Jr., Leon L.
机构
来源
| 1979年
关键词
BIOLOGICAL MATERIALS - Measurements - FLUORESCENCE - Measurements - LASER BEAMS - Applications - PATTERN RECOGNITION SYSTEMS - Computer Applications;
D O I
暂无
中图分类号
学科分类号
摘要
A new slit-scan type flow system is described which provides three (X, Y, and Z) orthogonal one-dimensional projections of cell fluorescence. A photomultiplier tube and two semiconductor array detectors are used to obtain the three slit-scan contours from cells traversing a single fluorescence excitation beam. A high speed, dedicated preprocessor analyzes the three contours in parallel, extracting certain features useful for rejecting cells from which an accurate measurement of nuclear fluorescence cannot be obtined. Contour data is buffered and transferred to a PDP-11/40 compuer where nuclear fluorescence is measured and cells are classified. It is anticipated that this new instrument will provide a significant reduction in false alarm rate when applied to prescreening of gynecologic cytology specimens.
引用
收藏
页码:321 / 324
相关论文
共 50 条
  • [31] FALSE ALARMS IN A SLIT-SCAN FLOW SYSTEM - CAUSES AND OCCURRENCE RATES IMPLICATIONS AND POTENTIAL SOLUTIONS
    WHEELESS, LL
    CAMBIER, JL
    CAMBIER, MA
    KAY, DB
    WIGHTMAN, LL
    PATTEN, SF
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) : 596 - 599
  • [32] SLIT-SCAN FLOW-CYTOMETRY - SEPARABILITY PROPERTIES OF CELL FEATURES
    MANN, RC
    CYTOMETRY, 1983, 3 (04): : 257 - 261
  • [33] MULTIDIMENSIONAL SLIT-SCAN DETECTION OF BLADDER-CANCER PRELIMINARY CLINICAL-RESULTS
    WHEELESS, LL
    BERKAN, TK
    PATTEN, SF
    REEDER, JE
    ROBINSON, RD
    ELDIDI, MM
    HULBERT, WC
    FRANK, IN
    CYTOMETRY, 1986, 7 (02): : 212 - 216
  • [34] SIGNAL-PROCESSING IN SLIT-SCAN FLOW-CYTOMETRY OF CELL CONJUGATES
    SCHUT, TCB
    FLORIANS, A
    RADOSEVIC, K
    DEGROOTH, BG
    GREVE, J
    CYTOMETRY, 1993, 14 (04): : 459 - 464
  • [35] SCAN - A PROGRAM LIBRARY FOR HIGH-RESOLUTION SLIT-SCAN ANALYSIS OF CHROMOSOMES IN FLOW-CYTOMETRY
    WEIER, HU
    EISERT, WG
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1986, 23 (03) : 269 - 276
  • [36] SLIT-SCAN CYTOFLUOROMETRY - DATA BASE FOR AUTOMATED CYTOPATHOLOGY
    WHEELESS, LL
    PATTEN, SF
    CAMBIER, MA
    ACTA CYTOLOGICA, 1975, 19 (05) : 460 - 464
  • [37] DICENTRIC CHROMOSOME FREQUENCY-ANALYSIS USING SLIT-SCAN FLOW-CYTOMETRY
    LUCAS, JN
    MULLIKIN, JC
    GRAY, JW
    CYTOMETRY, 1991, 12 (04): : 316 - 322
  • [38] A NEW COMBINED INTEGRAL-LIGHT AND SLIT-SCAN DATA-ANALYSIS SYSTEM (DAS) FOR FLOW-CYTOMETRY
    BEISKER, W
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 42 (01) : 15 - 26
  • [39] 2-PARAMETER DATA-ACQUISITION SYSTEM FOR SLIT-SCAN CHROMOSOME ANALYSIS
    WEIER, HU
    EISERT, WG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (11): : 2902 - 2902
  • [40] Image-Based Scanpath Comparison with Slit-Scan Visualization
    Koch, Maurice
    Kurzhals, Kuno
    Weiskopf, Daniel
    2018 ACM SYMPOSIUM ON EYE TRACKING RESEARCH & APPLICATIONS (ETRA 2018), 2018,