Model for the evaluation of no-load losses of three-phase transformers with distorted fluxes

被引:0
|
作者
Arturi, C.M. [1 ]
Ubaldini, M. [1 ]
机构
[1] Politecnico di Milano, Italy
来源
Energia Elettrica | 1988年 / 65卷 / 11期
关键词
Electric Losses - Electric Windings; Transformer - Mathematical Models;
D O I
暂无
中图分类号
学科分类号
摘要
This paper considers the influence of the winding connection and the distortion in the supply voltage on the no-load loss in three-phase core-type transformers. With sinusoidal supply voltage, this analysis shows that the no-load loss is greater in delta connection than in star connection of the supplied side and that, in the latter case, it depends on the connection of the secondary side: the loss is greater if the secondary is delta-connected than star-connected. The differences might be even of the order of 5-6%. The distortion of the supply voltage increases the previous figures, i.e., the no-load loss is greater than that with sinusoidal voltage if the winding is delta-connected. The paper also discusses the formula of the Standard for the correction of the measured no-load loss to the sine wave basis and proposes a circuit model for computing the effect of the distortion of the supply voltage.
引用
收藏
页码:477 / 484
相关论文
共 50 条
  • [21] Transient states in three-phase transformers
    Solbut, Adam
    Solbut, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (02): : 105 - 108
  • [22] Currents and magnetic fluxes of the three-phase core-type delta-wye and wye-delta connected trasformer on no-load operation
    Simkevicius, Tedoras
    Lape, Romanas Jonas
    ECT 2007: ELECTRICAL AND CONTROL TECHNOLOGIES, PROCEEDINGS, 2007, : 194 - +
  • [23] Analysis of ferroresonance in three-phase transformers
    Lesieutre, BC
    Mohamed, JA
    Stankovic, AM
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1013 - 1018
  • [24] Asymmetry during load-loss measurement of three-phase three-limb transformers
    Escarela-Perez, Rafael
    Kulkarni, S. V.
    Kodela, N. K.
    Olivares-Galvan, Juan Carlos
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3360 - 3360
  • [25] A simplified calculation method of core losses considering rotating losses of electrical steel sheets in three-phase transformers
    Zhang, Yanli
    Liu, Yang
    Xie, Dexin
    Bai, Baodong
    Song, Chengzhi
    Zhang, Wei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (18): : 126 - 131
  • [26] Asymmetry during load-loss measurement of three-phase three-limb transformers
    Escarela-Perez, R.
    Kulkarni, S. V.
    Kodela, N. K.
    Olivares-Galvan, J. C.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) : 1566 - 1574
  • [27] Simple and Accurate Algorithm for Three-Phase IM Efficiency Estimation from Only No-Load Tests
    Al-Badri, Maher
    Pillay, Pragasen
    Angers, Pierre
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [28] Features of Defining Three-Phase Transformer No-Load Parameters by 3D Modeling Methods
    Yarymbash, D.
    Yarymbash, S.
    Kylymnyk, I.
    Divchuk, T.
    Litvinov, D.
    2017 INTERNATIONAL CONFERENCE ON MODERN ELECTRICAL AND ENERGY SYSTEMS (MEES), 2017, : 132 - 135
  • [29] Harmonies of the currents and magnetic fluxes of the three-phase core-type delta-wye and wye-delta connected transformer on no-load operation
    Simkevicius, Teodoras
    Lape, Romanas Jonas
    PROCEEDINGS OF THE XVII INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DISTURBANCES, EMD 2007, 2007, : 260 - 265
  • [30] Thermal problems caused by harmonic frequency leakage fluxes in three-phase, three-winding converter transformers
    Forrest, JAC
    Allard, B
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) : 208 - 213